General characteristics

Admissible fluid
Motor protection
Admissible fluid temperature
Noise level
Dimensions (LxWxH)
Break-tank volume
Discharge connection
Suction connection
City main water connection
Break-tank overflow
Net weight (+/- 10 %)
5.3

Dimensions

5.4

Scope of delivery

6

Description

6.1

Product description

Installation and operating instructions Wilo-RAIN3
Description
Wilo-RAIN3
PH 5 to 8
Integrated thermal protection probe
+ 5 °C up to + 30 °C
Up to 56 dB(A) (at 1 m from unit with wood plate wall in acoustic room)
642 x 260 x 715
11 liters
Rp 1" threaded swivel-nut
Rp 1" threaded swivel-nut
R 3/4" (male)
Install a drainage pipe Ø19-21 (to be provided by the customer). In case of a
very large leakage, an opening allows the water to flow freely according to EN
1717
30 kg
See Fig. 1
The Wilo-RAIN3 package includes:
See Fig. 2
ƒ
System,
ƒ
Level sensor,
ƒ
Screw anchors,
ƒ
Installation and operating instructions,
ƒ
Stickers "No drinking water" and "Do not allow to freeze/do not expose to frost".
The system features a self-priming centrifugal pump that delivers rainwater sucked
from a storage tank (Fig. 4, rep. 17) to the points of consumption trough installation
pipes (Fig. 4, rep. 16).
The controller (Fig. 3, rep. 2) simultaneously ensures:
ƒ
The water continuity by switching the three-way valve (Fig. 3, rep. 6) to the mains
water network when the rainwater level in the rainwater storage tank is too low.
ƒ
The automatic start and stop of the pump.
ƒ
The pump's dry-running protection in case of water shortage.
The 11-liters break-tank (Fig. 3, rep. 3.) is designed according to the EN1717 standard
(AB type disconnection) and ensures a separation of the rainwater from the mains net-
work by means of an air gap.
The break-tank is filled by city main water through a float valve (Fig. 3-4, rep. 4). In
case of failure, the water overflow goes freely to the drain. The hose collecting the
overflow (Fig. 3-4, rep. 9) is not included.
Fig. 3 and 4 legends
Black arrow: suction
White arrow: discharge
1.
Pump set
2.
Controller
3.
Break-tank
4.
Mains water network connection (G3/4")
5.
Level sensor to be installed inside the rainwater storage tank
6.
Three-way valve
7.
Discharge hose connection (G1" swivel nut)
8.
Suction hose connection (G1" swivel nut)
9.
Drainage connection towards wastewater (Ø19)
en
31