Maintenance; Cleaning The Cabinet; Interference - Gamko FK Mode D'emploi

Masquer les pouces Voir aussi pour FK:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Self-maintenance
• Before First use the cabinet should be cleaned using water and a mild detergent.
• Intensive use requires regular cleaning.
• The FK/MU, FK/VS has a lamellae condenser and this needs to be cleaned once a
week using a vacuum cleaner.
• Check and clean the magnetic seals on a regular basis. If the seal is not airtight it will
have a negative effect on the refrigeration performance and it needs to be replaced
immediately.
ATTENTION!
DO NOT DISMANTLE ANY FIXED COMPONENTS WHEN CLEANING THE MACHINE
UNIT!
DO NOT USE AGGRESSIVE ABRASIVES OR DETERGENTS.
The cabinet does not start.
• Check the plug.
• Restore the power supply by replacing a fault fuse or by using the on/off switch.
• Contact your local service organization.
Temperature is too high, in spite of recent adjustment of thermostat.
• Check/restore power supply.
• Remove contents which may obstruct ventilation.
• Clean magnetic seal, replace if necessary.
• Defrost evaporator.
• Check if the condenser if dirty
• Thermostat or compressor is defect.
• Fan (evaporator or condenser) is defect.
• Contact your local service organization.
Temperature is too low, in spite of recent adjustment of thermostat.
• Thermostat is defect.
• Contact your local service organization.
Water leak
• Defrost regularly – if necessary extra manual defrost cycle.
• Check if the product is leveled. If necessary level the product.
• Contact your local service organization.
Plug lead
• To prevent accidents the plug lead, if damaged, may only be replaced by the
service/maintenance organization or qualified installer.
User Manual
6.

Maintenance

6.1

Cleaning the cabinet

6.2

Interference

31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fk/muFk/vs

Table des Matières