Johnson AURUM R32 M Serie Guide D'utilisation page 164

Masquer les pouces Voir aussi pour AURUM R32 M Serie:
Table des Matières
Les langues disponibles

Les langues disponibles

Module protection
DC generatrix low voltage
protection
DC generatrix high voltage
protection
MCE malfunction
P6
Zero speed protection
Speed difference >15Hz
protection between
the front and the back clock
Speed difference >15Hz
protection between
the real and the setting speed
1. Check the Heat pump system pressure.
2. Check the phase resistance of compressor.
3. Check the U, V, W power line connection sequence
between the inventer board and the compressor.
4. Check the L1, L2, L3 power line connection between
the inventer board and the Filter board.
5. Check the inventer board.
75