Johnson AURUM R32 M Serie Guide D'utilisation page 150

Masquer les pouces Voir aussi pour AURUM R32 M Serie:
Table des Matières
Les langues disponibles

Les langues disponibles

3.1
HEAT MODE
3.2
t_T4_FRESH_H
3.3
T4HMAX
mode
3.4
T4HMIN
3.5
dT1SH
3.6
dTSH
3.7
t_INTERVAL_HEAT
3.8
T1SetH1
3.9
T1SetH2
3.10
T4H1
3.11
T4H2
3.12
ZONE1 H-EMISSION
3.13
ZONE2 H-EMISSION
The delay time for water pump to stop after the
3.14
t_DELAY_PUMP
compressor stops
4.1
T4AUTOCMIN
4.2
T4AUTOHMAX
5.1
WATER FLOW TEMP.
5.2
ROOM TEMP.
5.3
DOUBLE ZONE
HMI enable energy
5.4
Energy metering 0=NO 1=YES
metering
The style of room thermostat : 0=NO, 1=MODE
6.1
ROOM THERMOSTAT
SET, 2=ONE ZONE, 3=DOUBLE ZONE
7.1
dT1_IBH_ON
7.2
t_IBH_DELAY
7.3
T4_IBH_ON
7.4
dT1_AHS_ON
7.5
t_AHS_DELAY
7.6
T4_AHS_ON
7.7
IBH_LOCATE
IBH/AHS installation location PIPE LOOP=0;
7.8
P_IBH1
Power input of IBH1
7.9
P_IBH2
Power input of IBH2
7.10
P_TBH
Power input of TBH
The target outlet w ater temperature for space heating
8.1
T1S_H.A_H
w hen in holiday aw ay mode
The target outlet w ater temperature for domestic hot
8.2
T5S_H.A_DHW
w ater heating w hen in holiday aw ay mode
PREHEATING FOR
The setting temperature of outlet w ater during first
12.1
FLOOR T1S
preheating for floor
12.3
t_FIRSTFH
The time last for preheating floor
Enable or disable the heating mode
The refresh time of climate related curves for heating
mode
The maximum ambient operating temperature for heating
The minimum ambient operating temperature for heating
mode
The temperature difference for starting the unit (T1)
The temperature difference for starting the unit (Ta)
The start time interval of the compressor in HEAT mode
The setting temperature 1 of climate related curves for
heating mode
The setting temperature 2 of climate related curves for
heating mode
The ambient temperature 1 of climate related curves for
heating mode
The ambient temperature 2 of climate related curves for
heating mode
The type of zone1 end for heating mode : 0=FCU (fan coil
unit),1=RAD. (radiator) ,2=FLH (floor heating)
The type of zone2 end for heating mode : 0=FCU (fan coil
unit),1=RAD. (radiator) ,2=FLH (floor heating)
The minimum operating ambient temperature for cooling in
auto mode
The maximum operating ambient temperature for heating
in auto mode
Enable or disable the WATER FLOW TEMP.:0=NON,1=YES
Enable or disable the ROOM TEMP.:0=NON,1=YES
Enable or disable the ROOM THERMOSTAT DOUBLE
ZONE:0=NON,1=YES
The temperature difference betw een T1S and T1 for
starting the backup heater.
The time that the compressor has run before the first
backup heater turns on. Including the interval time
between two backup heater operating, If IBH is in
two-step control
The ambient temperature for starting the backup heater
The temperature difference betw een T1S and T1 for
turning the additional heating source on
The time that the compressor has run before starting the
additional heating source
The ambient temperature for starting the additional
heating source
61
1
0
1
0.5
0.5
6
25
20
35
-15
-25
30
5
2
20
2
1
10
5
5
5
35
25
65
28
25
65
-5
-25
35
7
-25
35
1
0
2
2
0
2
2
0.5
20
25
20
29
17
10
17
1
0
1
0
0
1
0
0
1
1
0
1
0
0
3
5
2
10
30
15
120
-5
-15
30
5
2
20
30
5
120
-5
-15
30
0
0
0
0
0
20
0
0
20
2
0
20
25
20
25
25
20
25
25
25
35
72
48
96
1
/
0.5
hours
1
ºC
ºC
1
1
ºC
ºC
1
1
MIN
1
ºC
1
ºC
ºC
1
1
ºC
1
/
1
/
0.5
MIN
1
ºC
ºC
1
1
/
1
/
1
/
1
/
1
/
1
ºC
5
MIN
1
ºC
1
ºC
5
MIN
1
ºC
0
/
0.5
kW
0.5
kW
0.5
kW
1
ºC
1
ºC
1
ºC
12
HOUR
V.1

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Aurum r32 m vma

Table des Matières