Johnson AURUM R32 M Serie Guide D'utilisation page 114

Masquer les pouces Voir aussi pour AURUM R32 M Serie:
Table des Matières
Les langues disponibles

Les langues disponibles

9.3.2 1-phase for 4-16kW units
1) PCB A, 4-10kW, Inverter module
Remarks: for 4-6kw, two capacitors
9
8
Code
Assembly unit
1
Compressor connection port U
2
Compressor connection port V
3
Compressor connection port W
4
Output port for +12V/9V(CN20)
5
Port for fan(CN19)
2) PCB A, 12-16kW, Inverter module
CN502
CN501
10
9
Assembly unit
Code
1
Compressor connection port U
2
Compressor connection port V
3
Compressor connection port W
4
Port for fan (CN19)
5
Output port for +12V/9V (CN20)
1
2
3
CN20
4
5
7
6
Code
6
Reserved(CN302)
7
Port for communication with PCB B(CN32)
Input port N for rectifier bridge(CN502)
8
9
Input port L for rectifier bridge(CN501)
/
1
2
3
4
CN19
CN6
8
Code
6
Port for communication with PCB B(CN32)
7
Port for high pressure switch (CN23)
8
Reserved (CN6)
9
Input port L for rectifier bridge (CN501)
10
Input port N for rectifier bridge (CN502)
25
Assembly unit
/
CN20
5
CN32
6
7
CN23
Assembly unit
V.1

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Aurum r32 m vma

Table des Matières