Télécharger Imprimer la page

Inventum IKA8045 Manuel D'utilisation page 42

Masquer les pouces Voir aussi pour IKA8045:

Publicité

3. Clean the grille and the grease filter by soaking them in hot soapy water.
a. Use a brush to clean the grille and the grease filter.
b. Do not use aggressive, acidic or alkaline cleaning product.
c. If necessary, use a special grease solvent.
4. Rinse the grille and the grease filter thoroughly.
5. Allow the grease filter to drain.
6. Dry the components. Use a dry tea towel.
7. If necessary, clean the grease filter in a dishwasher at a maximum temperature of 70°C.
Note:
The grease filter can change color after cleaning. This is normal.
CLEANING AND REPLACING THE LONGLIFE CARBON FILTERS
Clean the longlife carbon filters regularly in order to maintain a good working order of the filters. When the control
panel displays "FC", it means the longlife carbon filter need to be replaced.
Note:
This procedure is only valid if you installed the longlife carbon filters in your appliance.
Note:
It is recommended to set the automatic shut-off of the hood at 10 minutes. This way, the carbon filters
can regenerate. Refer to section
(Figure 5)
Cleaning the longlife carbon filters
1. Remove the grille and the grease filter.
2. Remove the carbon filters and clean them according to one of the below options: a or b.
a. Place the carbon filters in the dishwasher, add detergent, and use a standard program (1.5 to 3 hours) to
clean.
b. Soak the carbon filters in hot water (60-80 °C) for 1 or 2 hours, add detergent to the hot water and rinse the
carbon filter with clean water after soaking.
3. Dry the carbon filters according to one of the below steps before placing them back in the appliance.
Drying the longlife carbon filters
1. Dry the carbon filters before placing them back in the appliance according to one of the below options: a or b.
a. Place the cleaned carbon filters in the oven and bake for 3 hours at 150 °C.
b. Use a warm blow dryer to dry it for 0.5 hour.
Note:
Replace the longlife carbon filters at least every 5 years.
Do not use highly alkaline or heavy oil-based detergents, as they may cause damage to the carbon
filters. We recommend using dishwashing detergents from Finish, Ecover or Somat.
The temperature of the hot water should not exceed 80 °C, as this may cause damage to the carbon
filters.
Do not exceed a baking temperature of 200 °C, as this may cause damage to the carbon filters.
Do not scrub the carbon filters, as this may cause damage to the filters.
CLEANING THE CAVITY AND DRAINAGE
In case of spills, it might be necessary to clean and drain the cavity. Remove the grille and the grease filter before
cleaning the cavity.
42
English
Using the automatic shut-off mode of the hood
.

Publicité

loading