OPERATION
CHARGING RIDGID LITHIUM-ION
BATTERY PACKS
Lithium-ion batteries deliver fade free power for their entire
run time. 18 V lithium-ion tools will not gradually lose power
due to decreasing battery charge. Instead, power from the
battery pack will drop from full to zero once the full charge
has been drained from the battery. Once this happens,
recharging of the battery is required.
It is not necessary to drain the battery pack completely
before recharging.
CHARGE STATUS LEDS
See Figure 3, page 10.
MODE
Power
Charger is connected to power source.
Ready to charge battery pack.
Evaluate
Preparing battery pack for charging.
Charging
Restoring energy to battery pack.
Charged
Fast charging is complete. Charger
enters maintenance charge mode.
Standby / Charged
Battery pack is fully charged and charger is
in Energy Save mode.
Temperature
The battery pack is either too hot or cold
to accept a charge. When the battery
pack reaches a proper temperature,
charging will resume.
Defective
Battery pack or charger is defective.
RIDGID LITHIUM-ION BATTERY PACKS WITH
FUEL GAUGE
When RIDGID Lithium-ion battery packs R840083 or
R840085 are placed on the R840093 charger, the fuel gauge
will indicate the charge level as shown in the following chart.

COLD WEATHER OPERATION

The lithium-ion battery pack can be used in temperatures
down to -4°F. Put the battery pack on a tool and use the tool
in a light duty application. After about a minute, the pack will
warm up and begin operating normally.
GREEN LED
GREEN LED
On / Fading
On
On
Flash
On
On
Fade
Fade
Fade
Fade
Flash
On
On
On
On
7 — English
ORANGE
ORANGE
LED
LED
Flash
Fade
FUEL GAUGE
Flash
On
Flash
On
On
Flash
On
On
On
RED LED
Fade
CHARGE LEVEL
0-25% Charged
25-50% Charged
50-75% Charged
75-100% Charged
100% Charged

Publicité

loading