Télécharger Imprimer la page

AIRFORCE INNOVA VISIO PLUS 90 Prescriptions De Montage Et Mode D'emploi page 34

Publicité

EN
I
MAINTENANCE
Filters and collect tray
Grease filters
In the display of the extraction unit, 'F' and 'G' will be shown alternately after 30 operating hours of the extraction
unit. The grease filters should now be cleaned.
These must be cleaned once a month (or when the filter saturation indication system indicates this necessity).
Do not use aggressive cleaning agents and preferably clean the filter manually or in the dishwasher at a low
temperature and with a short program. Place the filters with the opening downwards in the dishwasher so that the
water can run out. The cleaning agents used in dishwashers make the aluminum dull faster. This is normal.
After the cleaning and replacing of the grease filters, reset the memory of the filter saturation indication.
Recyrculation filters - (cod.AFCFCAIV)
Filters can be restored in the oven, better if fan-assisted.
Temperature of the oven should be 150°-180°, higher temperatures could damage the filters.
It is better to place the filter bricks on the oven's grid, non pre-heated, and let them cool down
completely before removing.
The time needed to restore the filters is at least two hours or even more, depending on the
cooking intensity. Restoring should be done only in a well-ventilated place.
Do not wash the filters in the dishwasher.
Recyrculation filters can be restored many times, but for a better efficiency we recommend to
replace every 5 years.
Recyrculation filters Twin- (cod.AFCFCAISOB02)
Washable filters (also called Long Life) are regenerable.
They must be washed without detergents.
They can be washed in the sink with hot water or they can be put in the dishwasher with a quick wash, without
dishes (to avoid the presence of fats or oils) at recommended temperatures not exceeding 60/65°C - times of
6/7 minutes.
Drying:
the filters can be dried naturally by covering them with a clean cloth that does not leave residues or in a static
oven at temperatures of 60°C for no more than 15 minutes.
NB. Drying must never be done with air flows.
ATTENTION: the TWIN FILTERS must be replaced after 240 hours of use, corresponding to the second reset/
replacement warning of the carbon filters, indicated by the appearance of the FG symbols, or at the 8th
regeneration of the filter.
It is necessary to replace the Twin filters:
• when you notice that the filtering of odors is no longer sufficient (the average time is after 240 hours of
operation).
• at the latest after 1 year of use.
• when the filters are clearly damaged.
ATTENTION: Drying must never be carried out with air flows. It is important that the TWIN filters are properly
dried before installation. After the maintenance, reset the memory of the filter saturation indication.
FUNZIONAMENTO
OPERATION
34
34

Publicité

loading