Commissioning; Electrical Connection; Menu Navigation - Weller Zero Smog 4V Mode D'emploi

Masquer les pouces Voir aussi pour Zero Smog 4V:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

3. Commissioning

3.1 Electrical connection

The supply voltage must be checked against the machine
name plate details prior to switch on. If correct then connect
the Zero Smog 4V to the mains and switch on at the
machine main switch (5).

3.2 Menu navigation

Start screen
Standard mode
Submenu
Submenu
Display after power-on
BL = bootloader version
FW = firmware version
Z E R O S M O G 4 V
V E R B L . F W
Default operating mode
The speed (30-100%) can be entered using the UP/DOWN
keys.
SPEED
MANUAL
3.3 Submenu functions
To select a menu item, press the Menu key. Each time the
Menu key is pressed, the next menu item is selected. The
display automatically returns to the default operating mode
after five seconds.
3.3.1 Filter time display
Displays filter time (filter operating hours) elapsed since last
"Reset".
FILTER TIME
CURRENT
OFF
> 100%
0
HOURS
3.3.2 Specified filter time
Specifies the fixed nominal filter life/nominal filter operating
hours
Adjustable from one hour to 999 days
Default setting as-delivered 200 days
After this time expires, the unit switches to "red"
and an audible signal also sounds
FILTER TIME
DEFAULT
3.3.3 Reset filter time
Resets the elapsed filter operating hours to zero
FILTER TIME
RESET
3.3.4 Pressure control / automatic speed control
When the extractor arm is open, the required suction capa-
city / flow rate is set manually in the default operating mode
by adjusting the turbine speed. If the pressure control func-
tion is activated, the turbine speed is adjusted automatically
as soon as further extractor arms are opened. This allows a
constant flow rate to be maintained under changing num-
bers of open extractor arms.
PRESSURE
CONTROL
SPEED
AUTOMATIC
3.3.5 Automatic OFF
If this function is activated, the unit switches automatically
to OFF mode on expiration of the set time (the turbine and
backlit display are turned off)
Adjustable from one hour to 7 days
OFF
AUTOMATIC
3.3.6 Selecting menu navigation language
Select from the following user languages: D, F, E, I, GB
SELECT
LANGUAGE
3.3.7 Unit number
An internal unit number is assigned to each unit.
English
OFF
NO
ON
> 100 %
10
HOURS
GB
18

Publicité

Table des Matières
loading

Table des Matières