π
H-1101
DELUXE PALLET
TRUCK SCALE
OPERATION
1. ON/OFF. Press and hold 1 second to turn scale on
and off. Scale runs a self-test, then displays the
product ID (left number) and software version (right
number.)
2. NUMBER KEYS. Use these keys to enter numbers. Also
used for other functions as labeled.
3. ENTER. Press after keying a number.
4. CLEAR. Press to clear the number in the display.
5. ZERO. Press ZERO to reset the display to zero with or
without a weight on the load cell.
• Nothing on the load cell – Resets the display to zero.
• Weight on the load cell – Resets the display to
zero, in effect canceling the weight of that item.
Useful for canceling the weight of the empty box or
container that will hold the items you want to weigh.
Display shows a negative number if you remove the
container, until you re-zero the scale.
• AZT (Auto Zero Tracking) – Corrects slight zero
changes during normal operation. If small weights
are added while display is at or near zero, the scale
may zero them off.
6. NET/GROSS. Switches display readout between net
weight and gross weight. Indicator on left side of
display shows whether gross or net weight is being
displayed.
NET = GROSS – TARE
• Weight is always "NET" when in "UNITS/PIECES."
• "E-2" Error displays if NET/GROSS key is pressed when
a total is set. Clear the current total before switching
between NET/GROSS.
PAGE 1 OF 3
1-800-295-5510
uline.com
INSTRUCTIONS
7. TARE. Set the weight of an empty container, so you
can cancel that weight from the total of items
being weighed.
• Place empty container on scale. Press TARE. Weight
of container is now entered in memory. When
weighing container with contents, pressing TARE will
cancel the weight of the container from the total.
Display will show the net weight.
• To clear tare, press TARE and CLEAR keys
simultaneously.
8. Tare does not function in UNIT/PIECES mode.
9. PRESET TARE. If the weight of a container is known, set
that weight in the memory manually.
• Press PRESET TARE, then key in the weight you want to
set.
• To clear, press TARE and CLEAR keys at the same
time.
10. UNITS/PIECES. Switches display readout between "lb"
and "kg" (kilograms) and "PCS" (pieces, quantity of
items.) Indicators are on left side of display.
11. SAMPLE. Displays weight of individual pieces.
• Place 3-5% of the total number of items being
weighed on the scale. Press SAMPLE. Use the number
keys to enter the number of items on the scale. The
sample measurement is saved in memory. The scale
will switch to the unit "PCS" and display the number
of pieces on the scale.
• To clear the sample memory, press the SAMPLE and
CLEAR keys at the same time.
Para Español, vea páginas 4-6.
Pour le français, consulter les pages 7-9.
0816 IH-1101
Table des Matières
loading

Sommaire des Matières pour Uline H-1101

  • Page 1 Para Español, vea páginas 4-6. Pour le français, consulter les pages 7-9. π H-1101 1-800-295-5510 uline.com DELUXE PALLET TRUCK SCALE INSTRUCTIONS OPERATION 7. TARE. Set the weight of an empty container, so you can cancel that weight from the total of items 1.
  • Page 2: Replace Batteries

    INSTRUCTIONS CONTINUED 12. APW (Average Piece Weight) If the weight of an 14. PEAK HOLD. Memorizes the maximum weight individual item is known, you can set that weight in applied. When in peak mode, the scale will not the scale manually. display any weight less than the maximum weight.
  • Page 3 EEPE EEPROM error Calibration is corrupted or gone. Scale requires recalibration. CONTROLS π CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA 1-800-295-5510 uline.com PAGE 3 OF 3 0816 IH-1101...
  • Page 4 π H-1101 800-295-5510 uline.mx BÁSCULA CON PATÍN HIDRÁULICO DE ALTA CALIDAD INSTRUCCIONES FUNCIONAMIENTO 7. TARE (tara). Fije el peso de un contenedor vacío, de forma que pueda restar dicho peso del total de ON/OFF (encendido y apagado). Presione y mantenga artículos que desea pesar.
  • Page 5 CONTINUACIÓN DE INSTRUCCIONES 12. APW (Average Piece Weight/Peso promedio por pieza) 14. PEAK HOLD (máximo sostenido). Memoriza el Si conoce el peso de un artículo individual, introduzca máximo peso aplicado. Cuando está en modo dicho peso en la báscula de forma manual. "peak"...
  • Page 6: Solución De Problemas

    La calibración se ha corrompido o se ha borrado. La báscula necesita ser recalibrada. CONTROLES π CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA 800-295-5510 uline.mx PAGE 6 OF 6 0816 IH-1101...
  • Page 7: Fonctionnement

    π H-1101 1-800-295-5510 uline.ca TRANSPALETTE PESEUR DE LUXE INSTRUCTIONS FONCTIONNEMENT 7. TARE. Définit le poids d'un récipient vide afin que vous puissiez déduire ce poids du total des éléments 1. ON/OFF (marche/arrêt). Maintenez la touche pesés. enfoncée pendant une seconde pour allumer ou •...
  • Page 8: Remplacement Des Piles

    INSTRUCTIONS SUITE 12. APW (Average Piece Weight/Poids moyen d'un 14. PEAK HOLD (Sauvegarder le maximum). Garde élément) – Si le poids d'un élément individuel en mémoire le poids maximal appliqué. En mode est connu, vous pouvez enregistrer ce poids en « peak », la balance n'affichera aucun poids mémoire manuellement.
  • Page 9: Dépannage

    La balance doit être étalonnée à nouveau. COMMANDES π CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA 1-800-295-5510 uline.ca PAGE 9 OF 9 0816 IH-1101...

Table des Matières