Operating Instructions CORREX
DC-voltmeter (e.g. digital multimeter or CorroScout
the instrument must be set to the 20 V DC range, the negative probe of the
instrument connected to the tank and the positive probe to the titanium
anode. The drive potential applied must be U > +2,3 V DC. Observe the '+'
sign. For this measurement, the tank must be filled with water and the
plug-in potentiostat connected.
Pilot lamp (11) green: mains supply established and CORREX
to operate.
Pilot lamp (11) off: probably no mains voltage.
Pilot lamp (11) flashing red: malfunction of the system. In this case, the
installation, it can be assumed that the malfunction is due to inappropriate
installation. Check and eliminate the fault in accordance with the
instructions set out in chapter 9.
7.2
CORREX
UP 2.3-919 for insulated-hole mounting
®
7.2.1 Safety instructions for fitting:
connections must be checked with a suitable measuring instrument (e.g
digital multimeter or CorroScout
34
UP 2.3-919
®
®
®
®
®
500).
®
500). For measuring,
®
UP ready
®