Installation And Commissioning; The Function Of The Correx ® Up System Is Only Ensured If All Electrical; Note: Observe The Instructions Set Out In Chapter 2.3 Above; Remove Any Existing Magnesium Protection Anode Before Installing The Correx ® Up System (In Case Of Retrofitting) - Magontec Correx UP 2.3-919 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7
Fitting and commissioning
7.1
CORREX
UP 2.3-919 for sleeve mounting
®

Note: Observe the instructions set out in chapter 2.3 above

7.1.1 Safety instructions for fitting:
1. Remove any existing magnesium protection anode before installing the
CORREX

2. Never connect the plug-in potentiostat to magnesium protection anodes.

3. The titanium anode must not be in direct contact with internal tank

components or with the tank wall. The quality of the insulation must be

checked with a suitable measuring instrument (e.g digital multimeter or
CorroScout

be immersed in water.

4. The function of the CORREX
parts are safely connected by metallic conductors. The quality of the
galvanic connections must be checked with a suitable measuring
instrument (e.g digital multimeter or CorroScout

5. Use only the original connecting cables

6. Never extend the connecting cables: otherwise risk of connection with
wrong polarity and thus of increased corrosion.

7. Check before commissioning that the cables are not interchanged.

Interchanging the cables results in increased corrosion.

8. For optimal results, the sealing ring needs a 60° chamfer at the sleeve.
Note: If the CORREX
sting threaded sleeves can be used, if necessary with reducers (galvanized
steel). Any tampering with system components such as the connecting cable
results in the expiration of the legal warranty.
7.1.2 Drawing: Fitting and commissioning
The illustration on the fold-out page (chapter 1.1) of this manual shows an
example of the installation procedure for a CORREX
fitting set. The actual situation depends on tank type, tank size, type of anode
and connecting cable used.
Note: Leave the fold-out page (chapter 1.1) open when installing the system.
The following parts are needed for installation:
1. Titanium anode with screw fitting G 3/4"-, G 1"-, G 1 1/4"
or with NPT thread (1)
2. Connecting cable (3)
3. Plug-in potentiostat (2)
UP system (in case of retrofitting).
®
500). During this measurement, the titanium anode must not
®
UP system is installed by way of retrofitting, any exi-
®
Operating Instructions CORREX
UP system is only ensured if all electrical
®
®
500).
®
UP system with screw
®
UP 2.3-919
31