INTRODUCTION
NOTE:
After the refrigerator is turned on, the Over
Temperature audio alarm and indicator
light may activate every 1¹⁄₂ hours until
the refrigerator and freezer temperatures
are below 48°F (9°C) and 15°F (-9°C),
respectively, or until the alarm is turned off.
To turn off the audio alarm and indicator
light, see "Master Alarm Reset."
The Cooling ON/OFF touch pad on the
control panel shuts down refrigerator
functions such as cooling, lighting, fans
and compressors. To turn the power off
completely, use the power ON/OFF switch
located behind the top grille. See "Power
On/Off Switch."
2.
Viewing the Celsius
Temperatures
Press the F/C touch pad. To redisplay
degrees Fahrenheit, press F/C again.
NOTE: If the freezer temperature is below zero,
the negative sign next to the freezer display will
light up. This is normal.
3.
Adjusting Controls
NOTE: Wait at least 24 hours between
adjustments. Recheck the temperatures before
other adjustments are made.
To Adjust Set Point Temperatures:
Press the refrigerator or freezer PLUS (+)
or MINUS (-) touch pad until the desired
temperature is reached.
Press the Set To Recommended touch
pad to reset the set points to the factory
recommended temperatures.
NOTE: The set point range for the freezer
is -5°F to 3°F (-21°C to -16°C). The set point
range for the refrigerator is 34°F to 42°F
(1°C to 6°C).
CONDITION/REASON:
TEMPERATURE
ADJUSTMENT:
REFRIGERATOR too
REFRIGERATOR
cold
Control 1° higher
Not set correctly for
conditions
REFRIGERATOR too
REFRIGERATOR
warm
Control 1° lower
High use or room very
warm
FREEZER too cold
FREEZER Control 1°
Not set correctly for
higher
conditions
FREEZER too warm/
FREEZER Control 1°
too little ice
lower
High use or heavy ice
use
4.
Water Filter Indicator and Reset
See "Water Filter Indicator" section.
5.
Max Cool
The Max Cool feature assists with periods
of heavy ice usage, full grocery loads, or
temporarily warm room temperatures.
Press MAX COOL to turn on the Max Cool
feature. The Max Cool indicator light will
remain on for 24 hours unless manually
turned off.
NOTE: The temperature display will remain at
34°F (1°C) and -5°F (-21°C) for the refrigerator
and freezer compartments, respectively, while
the Max Cool feature is enabled. After 24
hours, the refrigerator returns to the previous
temperature set points.
6.

Alarm Functions

Master Alarm Reset
Pressing Alarm Reset once will turn off the
audio alarm and indicator light. The audio
alarm will not sound again for the current
condition that caused the alarm until a new
condition occurs or until a Master Alarm Reset
is performed.
A Master Alarm Reset can be performed by
pressing Cooling (ON/ OFF) twice or by turning
the power to the refrigerator off and on again.
See "Power On/Off Switch." After performing
a Master Alarm Reset, the indicator light will
reactivate if the condition that caused the
alarm is still present. See "Over Temperature,"
"Call Service," or "Door Open."