Daily Use; Reloading With Firewood; Change Of Season; Cleaning The Window - Atra Atraflam Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- screw up some newspaper (or use birch bark) and place it
between the logs;
- cross kindling on top of this paper and light;
- add logs gradually and allow to burn briskly for several hours.
Then let the fi re go out.
N.B: risk of odour when using the appliance for the fi rst time.
Painted products. The fi replace may give off an irritating gas
and unpleasant odours when used for the fi rst time. This gas is
not toxic but you are advised to air the room thoroughly. Leave
the fi replace burning with a high draught until no more gas,
smoke or smell is given off.

4.5. Daily use

See the product technical sheet attached to this manual for
location of fi replace controls.
- open the primary air intake;
- open the damper;
- place two medium-sized logs at the back of the fi replace;
- screw up some newspaper (or use birch bark) and place it
between the logs, cross kindling on top of this paper and light.
Gradually add more logs;
- when the fi re is going well, shut the door and close the
damper;
- adjust the level of heat required using the primary air intake
control, after adding fi rewood. The fi replace always operates
with the damper closed.
4.6. Reloading with fi rewood
Warning! You are advised to wait until there are only ambers
left before adding more wood. Before fully opening the door,
open the primary air intake adjustment lever, and the damper
to equalise pressure.
- gradually open the guillotine door;
- add fi rewood and close the guillotine door;
- ensure that the primary air intake is opened completely for a
few minutes until the wood has caught fi re;
- close the damper;
- regulate the primary air intake to obtain the desired heat
level.
N.B: a half open door, allowing the fi re to draw too hard, or
excessive load may lead to the fi replace overheating.
Overheating occurs when the fi replace is overloaded with wood
and/or when the primary air intake is left open to
maximum. If necessary, reduce the air intake immediately, and
close the damper.
Obtain professional advice to deal with draught which appears
excessive or too weak.
4.7. Using the fi replace during the

change of season

When there is a change of season with sudden temperature
change, in cases of poor draught or strong wind, draught
problems can occur in the chimney and prevent smoke
evacuation.
evacuation.
In one of the above situations, it is recommended to use less
In one of the above situations, it is recommended to use less
wood and to open the air vents more to reduce smoke
wood and to open the air vents more to reduce smoke
emission and accelerate combustion. It ensures suffi cient
emission and accelerate combustion. It ensures suffi cient
draught. Remove ashes more frequently to avoid build-up.
draught. Remove ashes more frequently to avoid build-up.
10
5.0 Instructions for use

5.1 Cleaning the window

The ATRA insert has a "secondary air intake system" located at
the bottom of the door. This air sweeps the inside face of the
window, reducing the risk of deposits on the glass.
The amount of deposits depends on the level of humidity in the
fuel, draught conditions and air vent regulation. Most soot is
burned up when a brisk fi re is burned in the fi replace.
Hint: for standard cleaning, dampen a paper towel with hot
water, and then add some ashes from the combustion
chamber. Rub, and then clean the window with clean water and
dry with a soft, dry cloth. For optimum cleaning, you are advised
to use a special glass cleaner.
Never spray the product directly onto the glass: this may
damage the glass and seal fastenings, which may lead to the
window breaking.

5.2. Removing the ashes

This must only be done when the fi replace is completely out
and cold (no ambers)!
Rake the ashes, leaving a thin layer of cinders at the bottom of
the fi replace to protect it.
Warning, there may be some glowing ambers buried in the
cinder layer.

5.3. Cleaning soot deposits

Soot build-up may occur on the inside of the fi replace
during use, especially in the smoke chamber. Soot is a good
insulator. It therefore reduces the fi replace's heat production.
The soot deposit must be removed as soon as the build-up
becomes visible, to maintain optimal heat production. This may
be done during chimney and fl ue sweeping.
5.4. Sweeping the fl ue
The fl ue must be swept by a professional.
After sweeping, remove any soot deposits from the baffl es
inside the smoke chamber.
It is recommended to send a copy of the sweeping invoice to
the insurance company.
Sweeping : refer to the country's legislation.
5.5. Visual examination of the fi replace
ATRA advises users to check the fi replace carefully
themselves once a year following sweeping.
Also check that the seals are all in good condition and correctly
installed. Any seal showing signs of wear, distortion or
hardness must be replaced.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Atravision

Table des Matières