SEASONAL MAINTENANCE

Seasonal Maintenance is only required if you
have a cooler fitted with a bleed system. If your
cooler is fitted with a drain valve, no Seasonal
Maintenance is required.
Seasonal Maintenance services must be
performed before and after the summer
season.

Pre-Season

1. Remove the pad frames.
2. Ensure the power is off at the isolating
switch inside the cooler.
3. Gently wash the pad frames to remove any
dust build up during the winter. Note! Do
not wash the pads with high pressure water
spray. If pads are salted-up, replace them.
4. Check for water leaks. Check operation of
float valve.
5. Turn on the water supply to the cooler.
6. Switch on the isolating switch.
7. Refit the pad frames.
8. Run the cooler.
WARNING! Ensure pad frames are fitted when
operating the cooler.

End of Season

1. Turn off the water supply to the cooler.
2. Remove the pad frames
3. Turn off the power at the isolating switch
inside the cooler.
4. Check and clean the water distributing
spreader tray channels under the lid.
5. Drain the tank.
6. Thoroughly clean the tank, pump filter and
salinity probe (if fitted).
7. If a drain valve is fitted it will automatically
drain. If a bleed funnel is fitted, remove it
from the tank as shown below. Keep the
O'Ring in a safe place for later use.
2
8. Refit the pad frames.
|
8
INTERNATIONAL
1
1
ILL1141-A

Cooler Isolation Switch

Water Distribution Channels

ILL1141-A
ILL1O60-C
ILL1103-B