Make Gas Connection - Whirlpool W11241780A Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Drill two 1/8" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
A
B
A. #12 x 1
" screws (4.1 cm)
5
8
B. Anti-tip bracket
5. Using the two #12 x
" (4.1 cm) Phillips-head screws
1
5
8
provided, mount anti-tip bracket to the wall or floor.

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Apply pipe-joint compound made for use with propane gas
to the smaller thread ends of the flexible connector adapters
(see B and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and
the other adapter to the gas shutoff valve. Tighten both
adapters, being certain not to move or turn the gas pressure
regulator.
10
Wall Mounting
A
B
A. #12 x 1
" screws (4.1 cm)
5
8
B. Anti-tip bracket
3. Use a 15/16" (2.4 cm) combination wrench and an adjustable
wrench to attach the flexible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn when tightening
fittings.
H
G
F
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter [must have
1/2"(1.3 cm) male pipe thread]
D. Flexible connector
4. Gas supply pipe must be located within clearance area as
shown in the "Cabinet Dimensions" illustration in "Location
Requirements" section.
5. Plug in range to a grounded outlet. See the appropriate
"Electrical Requirements" section.
6. Slide range into place so that the rear range foot is inserted
into the slot of the anti-tip bracket.
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from parts
package. Align recess in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light. Place burner grates over burners and caps.
A
B
C
D
E
E. Manual gas shutoff valve
F. 1/2" (1.3 cm) or 3/4" (1.90 cm)
gas pipe
G. Use pipe-joint compound.
H. Adapter
B

Publicité

Table des Matières
loading

Table des Matières