6.2

SEttINGS IN PROGRaMMING MODE

Several settings must be entered before a battery can be charged in manual mode. This
will ensure optimum operation of the charger in manual mode:
Battery memory
Battery type
Cell count
Charge current
Discharge current
Battery capacity
Delta-V
Note:
The only values which can be changed are those in the first line when the symbol
is flashing.
SELECtING a BattERy MEMORy
M1
C:1.0A
NM
4S

SELECtING thE BattERy tyPE

BAT. TYPE
BAT. CELL
or LiFe.
SEttING CELL COUNt / BattERy VOLtaGE
BAT. TYPE
BAT. CELL

SEttING thE ChaRGE CURRENt

CH. CURR
DC. CURR
count
or battery voltage and the maximum charge power (Lithium batteries: max. 2C). If the
maximum charge power is exceeded, the charger's processor limits the maximum charge
current.
Operating Instructions
Power Peak ® B7 EQ-BID
You can choose any battery memory from 1 to 4.
D:1.0A
3600mAh
Select battery type NiMH, NiCd, Pb (lead-acid), LiPo,
NiCD
LIoN
4
This is where you select the number of cells in the
NiCD
battery.
4
The charge current can be selected in 0.1 A
+1.00A
increments. The available range is 0.1 A to 10 A. The
-1.00A
maximum charge current varies according to the cell
11