10) Replace the front cover by holding both sides, inserting the hooks into the holes, and securely attaching it to the magnet
catch. See "II. 3. FRONT COVER".
11) The remaining solution can be used to sanitise utensils.
Note: Do not wipe dry or rinse after sanitising, but allow to air dry.
[c] Grille, Drain Pan Cleaning/Sanitisation (Daily)
1) Either mix 1 litre of water with 4 ml of 5.25% sodium
hypochlorite solution in a suitable container, or the
recommended Hoshizaki sanitiser as directed.
2) Lift the grille off the drain pan.
3) Soak the grille in the solution for more than 3 minutes.
Rinse thoroughly, and shake to remove surplus liquid.
Note: Using a cloth to dry may re-contaminate.
4) Use the accessory brush to clean the three drain
holes in the drain pan.
5) Place the grille in its correct position and direction.
[d] Air Filter
To prevent injury, be careful not to touch the condenser fins when removing the air filter.
Plastic mesh air filters remove dirt or dust from the air, and keep the condenser from
getting clogged. If the filters get clogged, the ice dispenser's performance will be
reduced. Remove and clean the air filter(s) at least twice per month:
1) Pull out the air filter from the bottom of the drain pan.
2) Clean the air filter by using a vacuum cleaner. When severely clogged, use warm
water and a neutral cleaner to wash the air filter.
3) Rinse and dry the air filter thoroughly.
After cleaning, be sure to place the air filter back in position with the handle facing down.

2. INSPECTION AND MAINTENANCE

To achieve optimum ice dispenser performance, the following parts need periodic inspection and maintenance:
Extruding head (upper bearing)
Housing (lower bearing)
Mechanical seal
These parts should be inspected after two years from installation or 10,000 hours of operation, whichever comes first, and once
a year afterwards. Replacement of these parts is required if wear exceeds factory recommendations.
Their service life, however, depends on water quality and environment. More frequent inspection and maintenance are
recommended in bad or severe water conditions.
Consult with your local Hoshizaki service agent about inspection and maintenance service.
Lift
off
Grille
Drain Pan Top
CAUTION
NOTICE
NOTICE
11
ENGLISH
DCM-60/120KE
Grille must be
lower than the top
of drain pan.
Air Filter
Handle
DCM-60/120KE-P
Grille must be
level with the top
of drain pan.