Check the sealing (11). Replace the sealing if damaged or worn.
(Sealing Express 444 for powerjet 2,
Ensure that the sealing (11) is in place and in good condition.
Remove the white protective cap of the gas cartridge. Hold the cartridge (12) tightly and
insert it plain into the threaded screw connection of the adapter Express 444 (10).
Gently screw the gas cartridge in clockwise direction into the threaded screw connection.
Be careful not to fit the gas cartridge Express 444 (12) skewed.
!
Temperature range when using cartridges is +10°C to +35°C. (50°F to 95°F)

6. Routine service and maintenance

Gas cartridge adapter: Ensure that the sealing (9, 11) of the adapter is in place and in
good condition. Inspect every time you use the powerjet 2.
Replace the sealing if damaged or worn.
Sealing CV360 (9)
Art.No.: 6.006.010
Sealing Express 444 (11)
DVGW safety tubing: Pay attention to the warning and check the condition of the tubing/
hose frequently. Depending upon type of tubing/hose, hose clamps are required.
Replace the DVGW safety tubing at the latest after 10 years.

7. Warranty

The powerjet 2 is covered under our two-year manufacturer warranty against any
manufacture defects in material. The WLD-TEC warranty guarantees powerjet under
normal usage conditions and does not cover any damages as a direct result of
user misuse. The warranty is void upon any unauthorized servicing, disassembly
or modifications.

8. Technical Data

Type
Gas supply and
consumption
Connected load:
Gas types:
Temperatures
Flame temperature:
Temperature threshold
level:
Mechanical
Measurements:
Weight:
Art.No.:
6.006.085)
Art.No.: 6.006.085
powerjet 2
0,13 kg / h liquid gas
natural gas E/LL, liquid gas
II2ELL3B/P 20 - 50 mbar
Gas cartridge CV360 from Campingaz
(Campingaz / Coleman Part #: 39 352)
Gas cartridge Express 444 from
Guilbert Express
1350 °C on liquid gas
1300 °C on natural gas (E)
1,7 kW liquid gas
1 kW natural gas
W = 150 mm
H = 210 mm
500 g