Activating electrical components with positive (+) voltage
• Connect the proof tip to the positive terminal of the component. The LED is green.
• Watch the LED and push the rocker switch forward (+) and immediately release it again. If the
LED changes without delay from GREEN to RED, you may continue. If the LED extinguishes
or if the circuit breaker is released, the testing device is overloaded. This could be due to the
following reasons:
– The contact is a direct ground contact.
– The component has a short circuit.
– The component is a high amperage component (e.g. starter motor).
If the circuit breaker has been released, push the reset button.
Caution: If voltage is applied to certain circuits, this may cause damage to the
electrical components of the car. Therefore, it is strongly recommended to use the
corresponding circuit diagram and the appropriate diagnosis procedure for the
test.
1 2
V
Important notice: You can increase the life of your multifunctional testing device if,
while testing componennts, you operate the rocker switch before connecting the tip to the com-
ponent. The arcing will take place at the tip rather than at the switch contacts.
28
3
Design and Function
Do not use on electronic control units!
Motor