Technical Data; Description Of The Unit; Functional Principle; Unpacking The Unit - Air-O-Swiss E2441 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17

Technical data

Technical data
Value
Electrical voltage
Power consumption
Humidity output 
Suitable for rooms
Water capacity
Dimensions LxWxH
320 x 320 x 400 mm
Weight (empty)
Operation noise level 

Description of the unit

Description of the unit
The unit consists of the following components:
B 1
B 1
  F illing opening
B 2
B 2
  T op assembly
B 3
B 3
  F loat assembly (B 16–19)
B 4
B 4
  I onic Silver Stick
 (ISS)
®
B 5
B 5
  W ater base (B 5–7)
B 6
B 6
  W ater capacity fill line
B 7
B 7
  B ase handles
B 8
B 8
  S pout
B 9
B 9
  L ifecycle indicator for the Ionic Silver 
Stick
 (ISS)
®
B 10
B 10
  P ower cord/plug
B 11
B 11
  B ase (B 11–14)
B 12
B 12
  F an
B 13
B 13
  S lide switch (B 20–21)
B 14
B 14
  P ower rating plate (on the underside of 
the unit)
The float assembly consists of the following parts:
B 15
B 15
  F loat tip
B 16
B 16
  W ater level indicator ring (max. 3.8 l)
B 17
B 17
  E vaporator wick A7018
B 18
B 18
  F loat basket
B 19
B 19
  F loat body (styrofoam)
The slide switch consists of the following parts:
B 20
B 20
  S lide switch
B 21
B 21
  O perating light
Operating modes
The  following  operating  modes  can  be  set  on  the 
slide switch:
Position
Function
0
The unit is switched off
I
The unit is operating in night mode 
(low noise level)
The operating light turns green
II
The unit is operating in normal mode 
(maximum humidity output)
The operating light turns green
Operating light
The operating light illuminates green as soon as the 
unit  is  switched  on.  If  the  water  base  is  taken  off 
230 V / 50 Hz
the  base,  the  green  LED  changes  to  red  and  unit 
20 W
operation is interrupted, but the unit is not current-
up to 220 g/h
less.  Only  when  the  water  base  is  returned  to  the 
base does the red LED turn green again and the unit 
up to 40 m²
resumes operation.
max. 3.8 l
min. 0.2 l
Power rating plate
   
B 14
B 14
  The  following  information  is  displayed  on 
3.8 kg
the power rating plate:
< 25 dB(A)
Product name
Electrical voltage 
Power consumption
Protection class
Production number
Production date
The data on the power rating plate in the illustra-
tions is only exemplary. Please check the data on 
the power rating plate of your unit.

Functional principle

Functional principle
When filling the unit, the float switch is lifted with 
the water gauge. When the water gauge reaches the 
water  capacity  fill  line,  the  float  tip  closes  the  fill-
ing opening of the unit. The evaporator wick soaks 
up water. The fan pushes the dry room air through 
the moist mat and emits it as sufficiently moistur-
ized air. Through the directed guiding of the airflow, 
nearly  constant  humidification  is  possible  at  every 
water  level.  Therefore  the  unit  creates  optimum 
air moisture, without additional control units being 
necessary.
Ionic Silver Stick
nance
   
B 4
B 4
The specially adapted anti-microbial protec-
tion  system  Ionic  Silver  Stick
growth in the water in the water base. Therefore no 
chemical additives are necessary for water quality 
maintenance.
The Ionic Silver Stick
and can be used for a year.
Lifecycle indicator
   
B 9
B 9
The unit is equipped with a lifecycle indica-
tor  for  the  Ionic  Silver  Stick
current  month  on  the  label  and  write  the  current 
year on the line provided.  

Unpacking the unit

Unpacking the unit
At delivery the unit is completely assembled and 
already equipped with an evaporator wick. 
The  float  body  (styrofoam)  is  a  component  of 
the  float  assembly  and  does  not  belong  to  the 
packaging.
for water quality mainte-
®
  prevents  microbial 
®
 is self-renewing, service free 
®
®
.  Please  cross  off  the 
CAUTION
Risk of injury by falling parts!
Always  handle  the  unit  by  the  base  when  un-
packing and lifting. 
CAUTION
Damage to the unit due to removal of the float
body (styrofoam)!
Do  not  remove  the  float  body  (styrofoam)  when 
unpacking the unit. 
1.
Open the packaging.
2.
C 1
C 1
  Remove the upper part of the styrofoam 
packaging.
3.
C 2
C 2
  Reach into the filling opening and grasp 
the upper end of the plastic bag securely.
4.
C 3
C 3
  Carefully pull the plastic bag with the unit 
out  of  the  packaging. When  doing  so,  grasp  the 
plastic bag securely and do not let go of the plas-
tic bag when removing.
5.
C 5
C 5
  Place the plastic bag with the unit on the 
floor  and  push  the  plastic  bag  down  along  the 
unit.
6.
C 6
C 6
  Hold the unit by the base and lift up out of 
the plastic bag.
All packaging components as well as the plastic 
bag are removed from the unit.
7.
B 14
B 14
  Check data regarding the power supply 
on the power rating plate.
8.
B  B 
  Check that all components of the unit are 
included.

Putting the unit into operation

Putting the unit into operation
Positioning the unit
CAUTION
Damage to the plastic due to high tempera-
tures!
Do not expose the unit to temperatures > 50 °C. 
Observe the following pointers when positioning the 
unit:
A 14
A 14
  Remember  to  ensure  easy  accessibility 
and  sufficient  room  for  servicing  and  cleaning 
the unit.
Only operate the unit when it is filled!
1.
Place the unit on the floor or on a flat, dry surface 
in the room.
2.
Fill the unit (see chapter "Filling the unit").
Filling the unit
There  are  the  following  possibilities  for  filling  the 
unit with water:
using the filling opening on the upper part or
directly into the removed water base from a fau-
cet.
There are no foreign objects in the unit.
   
B B
  The unit is assembled properly.
9

Publicité

Table des Matières
loading

Table des Matières