Maintenance And Cleaning - Oase BioMaster 250 Notice D'emploi

Masquer les pouces Voir aussi pour BioMaster 250:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- EN -
TROUBLESHOOTING
Malfunction
Cause
No mains voltage
Unit does not
Impeller unit blocked
start up
Air in the filter
Impeller unit soiled
Impeller unit worn
The flow is not correctly set
Water flow
Foam filter of the pre-filter soiled
insufficient
Filter media in the filter unit soiled
Inlet strainer clogged
Pipework soiled
Foam filter of the pre-filter soiled
Foam filter of the pre-filter worn
Insufficient filtering
performance
Filter media in the filter unit soiled
Filter media in the filter unit worn
Heater defective
Insufficient water
Heater not calibrated
heating (Only
Water temperature incorrectly set on the
units with heater,
heater
→HeatUp manual)
Water flow insufficient
Valve box in the pre-filter blocked
The filter cannot be
vented
Filter is not below the surface of the water Install the filter below the surface of the water
Increased noise
Air in the filter

MAINTENANCE AND CLEANING

• If necessary, clean with clear water using a soft brush.
• Do not use cleaning agents or chemical solutions.
• Cleaning and replacement cycles for filter media are dependent on the size of the aquarium and the number
of fish. Therefore, it is necessary to clean and replace the filter media as required to ensure optimum filter
performance.
• If there are several filter foams: Clean or replace the filter foams at different times. This saves enough useful
bacteria to ensure good biological filtration of the water.
NOTE
Thoroughly rinse out all filter material with warm tap water before using for the first
time in order to remove any soiling. (→ Cleaning/replacing the filter media P.17)
16
Remedy
Check the mains voltage
Clean (→ P.19)
Vent the filter. Move the filter from side to side, if
necessary, to allow the remaining air to escape.
Clean (→ P.19)
Replace the impeller unit (→P.19)
Correct the setting (→ P.14)
Clean (→P.18)
Clean (→ P.18)
Clean
Clean inlet assembly, outlet assembly, and tubing
Clean (→ P.17)
Replace (→ P.17)
Clean (→ P.18)
Replace (→ P.18)
Replace
Calibrate
Correct the water temperature setting on the
heater
See malfunction "Water flow insufficient"
Clean the valve box (→ P.19)
Move the filter from side to side to allow the
remaining air to escape
BioMaster 250/350/600, BioMaster Thermo 250/350/600

Publicité

Table des Matières
loading

Table des Matières