Functional Safety Of The Sil Version; Relevant Standards - WIKA DPGS40TA Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Safety

2.3 Functional safety of the SIL version

2.3.1 General information
History of the information on functional safety
Issue
01/2016
The following information on functional safety is valid in conjunction with the other
parts of these operating instructions and with the documents mentioned in chapter
2.3.2 "Other applicable instrument documentation".
The operating instructions contain important information on handling the
DPGS40TA.100-xxS differential pressure gauge. Working safely requires that all
safety instructions and work instructions are observed.
Only model DPGS40TA.100-xxS is suitable for operation in safety-
related applications!
The marking on the product label for the instruments with SIL
version is shown in the following illustrations.
2.3.2 Other applicable instrument documentation
In addition to this section, the other parts of these operating instructions,
14106549, for model DPGS40TA.100-xxS, the data sheet PV 27.22 and the
certificates V 495.01/15 and V 495.02/15 (see Annex 3) also apply.

2.3.3 Relevant standards

Standard
IEC 61508 edition 2.0
IEC 61511 edition 1.0
ISO EN 13849-1:2008
WIKA operating instructions DPGS40TA with component testing
Remark
First issue in January 2016
Title
Functional safety of safety-related electrical/electronic/pro-
grammable electronic systems
Functional safety – Safety instrumented systems for the pro-
cess industry
Safety of machinery – Safety-related components of control
systems – Part 1: General principles for design
EN