Important Installation Information

GAS Type Verification

Verify the type of gas supplied to the location. Ensure that
the appliance is connected to the type of gas for which it is
certified. Ranges are certified for use with only natural gas
or propane (LP) gas. Make certain the range matches the
gas type available; these ranges are NOT convertible
between gas types.
Gas Supply:
Natural Gas — 6 inch water column. (14.9 mb) min., 14
inch (34.9 mb) maximum
Propane Gas — 11 inch water column. (27.4 mb) min., 14
inch (34.9 mb) maximum
WARNING:
To avoid possible burn or fire hazard, a backguard
designed specifically for this range must be installed
whenever the range is used.
IMPORTANT:
When installing against a combustible surface, a High Shelf
or Low Backguard is required. A THERMADOR
Shelf or Low Backguard must be purchased separately.
See Step 7 for backguard, kits and installation information.
When using the Flush Island Trim, THERMADOR
recommends a minimum 12" (305 mm) rear clearance to a
combustible surface (see Figure 1, Cabinet Clearances).
Clearances from non-combustible materials are not part of
the ANSI Z21.1 scope and are not certified by
CSA. Clearances of less than 12" (305 mm) must be
approved by the local codes and/or by the local authority
having jurisdiction.
Refer to the "Chart C: Backguard Kit Model Numbers" on
page 15, for the correct backguard models that are
designed for this range. After selecting the correct
backguard, the range must be installed properly, using the
minimum clearances to combustible surfaces specified in
the Cabinet Preparation instructions on page 4.
English 2

Electric Power Supply:

30" Model:
4 Burners — 120 VAC, 60 Hz., 1Ph., 10 Amp circuit.
36" Models:
6 Burners — 120 VAC, 60 Hz., 1Ph., 10 Amp circuit
4 Burners with Griddle — 120 VAC, 60 Hz., 1Ph., 20 Amp
circuit.
48" Models:
6 Burners with Griddle — 120 VAC, 60 Hz., 1Ph., 20 Amp
circuit.
When connecting the unit to propane gas, make certain
the propane gas tank is equipped with its own high-
pressure regulator in addition to the pressure regulator
supplied with the range. The maximum gas pressure to
this appliance must not exceed 14.0" water column (34.9
mb) from the propane gas tank to the pressure regulator.
This unit is designed as a cooking appliance. Based on
safety considerations, never use it for warming or
®
High
heating a room.
This appliance has been tested in accordance with ANSI
Z21.1, Standard for Household Cooking Appliances (USA)
and in accordance with CAN 1.1-M81 Domestic Gas
Ranges (Canadian). It is strongly recommended that this
appliance be installed in conjunction with a suitable
overhead vent hood (see "Step 1: Ventilation
Requirements"). Due to the high heat capability of this unit,
particular attention should be paid to the hood and duct
work installation to assure it meets local building codes.