31
UK
14 - GATE TRAVEL LEARNING
The procedure has two phases, completely automatic: the first one of OPENING and CLOSING SPACES
learning and the second one of motors' amperometric values learning.
If using only one motor, it must be connected to the terminals M1.
Intervention of START, PED, PHOTO1, PHOTO2, SAFETY inputs during learning procedure will abort the
procedure and it will be necessary to repeat it from the beginning.
During learning procedure FLASHING LIGHT / WARNING LIGHT will be on.
Travel learning movement is slowed down (50%).
Learning procedure cannot be executed while running on battery.
Learning procedure:
Release the operators and move the gates to halfway their travel.
Ÿ
Lock the operators.
Ÿ
Check that the mechanical opening and closing stops are present on the ground or on the operator.
Ÿ
Remove any obstacles in the range of action of the automated device.
Ÿ
Check that leds L3, L4, L5 and L9 are on.
Ÿ
Check that DIP 2_7 is in OFF
Ÿ
Press and release P1 button.
Ÿ
Led L8 will come on, after 30 seconds of no user interaction the control board will quit learning procedure.
Ÿ
Within 30 seconds press button 1 of the radio control or give a START pulse from the terminal board.
Ÿ
Check that motors' movement is in the correct direction (at the beginning in opening). On the contrary, block
Ÿ
the learning cycle with any safety device, invert the motor cables and repeat the procedure.
Movements during learning with 2 motors:
• Motor 1 opens until meeting the mechanical end-stops.
• Motor 2 opens until meeting the mechanical end-stops .
• 5 seconds pause.
• Motor 2 closes until meeting the mechanical end-stops.
• Motor 1 closes until meeting the mechanical end-stops.
• Full open-close cycle.
• End of learning; L7 will goes off.
Movements during learning with 1 motor:
• Motor 1 opens until meeting the mechanical end-stops.
• 5 seconds pause .
• Motor 1 closes until meeting the mechanical end-stops.
• It makes a complete manoeuvre, opening, 5 sec. pause and closing.
• End of learning; L7 goes off.
In case the learning procedure cannot be completed, please check LED L8 status (chapter 8).