4.3.
E
QUIPMENT REPAIRS
Disconnect the battery charger from the AC power network and disconnect the batteries before undertaking
any repairs.
When fuses have blown, only use fuses of the type and size recommended in this manual.
Please contact a reseller or ENAG for any other repairs.
5.
TECHNICAL SPECIFICATIONS
Models
Input
Voltage
Output power from 85 to 170Vac
Frequency
Current intensity 230/115Vac
Power factor
Efficiency
Input fuses
Sortie
Number of outputs
Total rated current (+/-7%) / Rated power
Load curve
Type of batteries
Regulated and filtered output voltage
Regulation tolerance before distributors and
fuses
Peak-to-peak ripple and noise
Output fuses mounted in the BAT pole -
Environment
Operating temperature
Cooling
Relative humidity
Storage temperature
Casing
Material
Paintwork
Dimensions excluding cable gland (length,
height, depth) / Weight
Fixing centre distances
Fixing screw (wall)
Protection factor
Board protection
Standards
CE/EMC marking
CE/safety marking
Electrical protections
All manuals and user guides at all-guides.com
CDS3/12-100
100%
7,4 A / 15,2 A
2 x 32A 400Vac
(10x38) (F1/F2)
1 separated output BAT 1
1 additional output +SP (before integrated distributor) for specific use, do not
connect it directly to a battery
Each output can be used on its own and supply the entire current.
100A/1425W
Type of charge selected using internal switch IU or IUoU (Boost, Absorption,
See selection wheel setting table. The chargers can operate on DC supply.
125A 150Vdc HRC
125LET (F3)
Rated conditions: from - 10°C to + 55 °C; over, de-rating : reduction of the output
Casing comprises :
Protected with water-repellent varnish (marine environment)
NF EN61000-6-1, NF EN61000-6-2, NF EN61000-6-3, NF 61000-6-4
- Against leaking input surges by rupture of VDR (voltage dependent resistor)
(not covered by warranty)
- Against output polarity reversals by rupture of fuses
- Against output short-circuits and surges
- Against abnormal overheating by cutting off the charger (internal temperature
probe 90°C), Automatic re-start
- Against output surges (17V
CDS3-1H-DED
CDS3/24-120
from 85 to 265VAC single phase
75%
From 47 to 65Hz
16,8 A / 26,2 A
0,9 in rated conditions
> 80% in rated conditions
2 x 32A 400Vac (10x38)
(F1/F2)
120A/3420W
Floating – factory setting).
See selection wheel setting table
< 2% (in rated conditions)
< 2% (in rated conditions)
160A 150Vdc HRC
160LET (F3)
power < than 2,5 %/°C up to 65°C
Continuous draft fans
Up to 70% (95% with no condensation)
-20°C to +70°C
Steel frame and steel front cover
Grey, black matt epoxy coating
350 x 400 x 123mm / 12,7Kg
328 x 292 mm
4 M5 round screws
IP22 (with cable glands)
NF EN60950, NF EN60335-2-29
±5% for12V)
±5% for 24V)
(34V
CDS3/48-60
75%
15,2 A / 23 A
2 x 32A 400Vac (10x38)
(F1/F2)
60A/3420W
80A 150Vdc HRC
80LET (F3)
-
Polycarbonate clasp
±5% for 48V)
(68V
26