Anchoring
Standard
Required anchor points
DIN 571 wood screw (diameter x length)
Rawl plugs (diameter x length)
With plinth (APWM)
Required anchor points
DIN 571 wood screw (diameter x length)
Rawl plugs (diameter x length)
Concrete plinth
Required anchor points
DIN 571 wood screw (diameter x length)
Rawl plugs (diameter x length)
Transport data, weight and floor load
Packaging width
Packaging height
Packaging depth
Gross volume
Gross weight*
Net weight*
Maximum floor load in operation*
*depending on equipment configuration
Emissions data
Workplace-related sound pressure level, washing
Sound power level, washing
Workplace-related sound pressure level, spinning
Sound power level, spinning
Average heat dissipation rate to installation room
Emission sound pressure level
en - Technical data
12 mm x 90 mm
16 mm x 80 mm
12 mm x 90 mm
16 mm x 80 mm
12 mm x 90 mm
16 mm x 80 mm
59,2 dB (A)
73,7 dB (A)
65 dB (A) re 20 µPa
2
4
2
750 mm
1214 mm
817 mm
744 l
152 kg
140 kg
2421 N
50 dB (A)
63 dB (A)
2,3 MJ/h
43