Control Elements (Head Plate)

Switch S1
S1: 1 ... 4
S1: 5 ... 6
Switch S2
S2: 1
S2: 2
S2: 3
S2: 4
S2: 5
®
VariTrans
P29000P2/00
Switch S2
Potentiometer (output offset, max. ± 5 %)
Zero
Power
Status LED (green)
Error
Alarm LED (red), flashes once when the device is switched on.
The safety alert symbol means: Read the user manual.
Switch S1
Open here!
Status Signal
Green LED: Supply voltage provided
Red LED:
Error: Check load. If the error cannot be remedied, send in
the device for repair.
Note: During switch-on, the red LED flashes briefly to
signal that the load monitor is functioning as intended.
48
Function (factory setting in bold)
Input range
Output range
ON
Active output
Voltage output
Inverted output
Cutoff frequency 10 Hz
Active offset pot.
Out
3
To check current output
during operation connect
ampere meter between
terminals 3.1 (-) and 3.3 (+)!
= Default
DIP Switch
In bipolar
In unipolar
-1000 to 1000 V
0 to 1000 V
-950 to 950 V
0 to 950 V
-900 to 900 V
0 to 900 V
-800 to 800 V
0 to 800 V
-750 to 750 V
0 to 750 V
-700 to 700 V
0 to 700 V
-600 to 600 V
0 to 600 V
-500 to 500 V
0 to 500 V
-450 to 450 V
0 to 450 V
-400 to 400 V
0 to 400 V
-350 to 350 V
0 to 350 V
-300 to 300 V
0 to 300 V
-250 to 250 V
0 to 250 V
-200 to 200 V
0 to 200 V
-150 to 150 V
0 to 150 V
-100 to 100 V
0 to 100 V
Special function:
Power supply: 24 V DC
± 25%, 1.5 W
VariTrans
DC/DC-Transmitter
Type
P29000P2/00
No.
80434/0000000
Tamb -25 to +70 °C
www.knick.de
14163 Berlin
01
Made in Germany
OFF
Passive output
Current output
Non-inverted output
Cutoff frequency 10 kHz
Calibrated meas. range
Power
S1
= On
Terminals
1
2
3 4
/
5.3 / 6.3
5.3 / 6.3
5.3 / 6.3
5.3 / 6.3
5.3 / 6.3
5.3 / 6.3
5.3 / 6.3
5.3 / 6.3
5.2 / 6.2
5.2 / 6.2
5.2 / 6.2
5.2 / 6.2
5.2 / 6.2
5.2 / 6.2
Bandwith 10 kHz
5.2 / 6.2
Bandwith 10 Hz
5.2 / 6.2
Calibrated ranges
Zero trim active (calibrated ranges off)
1.1 / 1.2
/
Test
Voltage:
®
U L
C
ES02
®
LISTED
80434
In +
5
1
S1
Out active Out passive
5
6 1
0
to
20
mA
0
to
-20
mA
4
to
20
mA
0
to
10
V
0
to
-10
V
4
to
20
mA
-20
to
20
mA
20
to
-20
mA
4
to
20
mA
4
to
20
mA
-10
to
V
10
10
to
V
-10
Input - Output/Supply 5.4 kV ~
Output - Supply
OPEN TYPE PROCESS
US
CONTROL EQUIPMENT
E340287
Reinforced insulation
Reinforced insulation
Basic insulation
1000 V CAT III
Reinforced insulation
Reinforced insulation
6
S2 Terminals
2
3
/
3.1 / 3.2
3.1 / 3.2
3.1 / 3.2
3.3 / 3.2
3.3 / 3.2
3.1 / 3.2
3.1 / 3.2
3.1 / 3.2
3.1 / 3.2
3.1 / 3.2
3.3 / 3.2
3.3 / 3.2
S2
4
S2
5
4.3 kV ~
600 V CAT II
300 V CAT III
600 V CAT II
300 V CAT III

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P29000p2/00P29000p2/01P29001p2/00P29001p2/01

Table des Matières