Top of connection board
Mains-powered units: Terminal L1, N, terminal
Voltage: 87 V AC...250 V AC
Internal connection
Cover on connection plate
Potential hazards grounding
Earth (ground) lead
Mains-powered units with back-up battery
If AMFLO
SONIC UFA-280 is mains-powered, a battery can be inserted as back-up power supply to ensure continuous operation in the
®
event of power failure. Depending on duration and numbers of mains power failures, battery has a lifetime of minimum 6 years (one battery).
(Average: one mains power failure per day (duration 1 hour) for min. 6 years).
Check that mains power supply symbol appears in display when installation is complete.This symbol indicates that installation is correct.
If mains power supply connection is not established correctly, flowmeter will operate on battery power only. Battery life will be significantly
shorter if batteries are used continuously as opposed to only occasionally in a back-up function.
AMFLO
SONIC UFA-280
®
Passive output
Open drain
Output A
Output B
Cable tie
Positive logic
Shielding
Negative logic
In mains-powered units protective earth wire must
be connected to PE
on printed circuit board
using connector.
Do not touch rear of printed circuit board.
External connection
Connection variants
Signal
Signal