english
. Liability for defects
Please read this information very carefully:
Liability for defects can only be accepted if the following
rules and the instructions for installation are complied
with.
Provided appropriate CLEARPOINT filters are being
used and the filter elements are replaced once a year,
the purchaser of the compressed-air membrane dryer
shall be entitled to claim remedy of defects within 2 years
from date of invoice.
BEKO shall not be liable for damage due to improper
or incorrect use, wear, storage or other actions by the
purchaser or third parties.
This applies in particular to wearing parts.
. Temperature
There must be no danger of frost at the place of instal-
lation; the temperatures at the place of installation and
of the compressed air should be between +35 and +140

Important information • Indicaciones importantes
6
5
7
3
DRYPOINT DM 10-41 C, 10-47 C, 20-48 C, 20-53 C, 20-60 C, 20-67 C
5
4
6
6
5
DRYPOINT M
®
°F. 3. Filters
Please observe the relevant filter requirements (see
page 8 - 9):
Dirt particles, oil residues and liquid condensate have
to be safely retained.
This requires the provision of a CLEARPOINT S su-
per fine filter (0.01 µm). With high dirt loads or large
amounts of condensate, it will be necessary to install a
CLEARPOINT F fine filter (1 µm) in addition and, where
appropriate, a W water separator.
Note: The filter elements need to be replaced once a
year.
4. Pipe between filter and membrane dryer
The membrane dryer must be located directly down-
stream of the last CLEARPOINT filter in order to avoid
renewed condensate formation. If a connection has to be
installed between the filter and the DRYPOINT M device,
this must be made of non-corroding material! Note: Do
not use any galvanized pipes or fittings between
filter and membrane dryer (corrosion)!