Blowing function
Cleaning hard to reach locations or, where
vacuuming is not possible, like leaves from
a gravel bed.
Illustration
 Connect the suction hose to the blower
connection, this will activate the blower
function.
Interrupting operation
 Turn off the appliance.
Illustration
 Hook the floor nozzle into the parking
position.
Finish operation
 Turn off the appliance and disconnect
the mains plug.
Empty the container
Illustration
 Remove the appliance head and empty
the reservoir filled with wet or dry dirt.
Storing the appliance
Illustration
H
 Store the accessories and the mains
2
cable on the appliance and store the
appliance in dry rooms.
Maintenance and care
Danger
Turn off the appliance and remove the
mains plug prior to any care and mainte-
nance work.
Repair works may only be performed by the
authorized customer service.
Caution
Do not use abrasives, glass or universal
cleaners! Never immerse the appliance in
water.
 Clean the appliance and accessory
parts made of plastic with a commercial
plastic cleaner.
 If required, rinse the container and ac-
cessories with water properly and dry
them before reuse.
Clean flat fold filter
I
Illustration
 For appliances without filter clean-
ing:
Release and open the filter flap. Re-
move the frame and filter and knock the
dirt out of the filter. Clean the filter under
running water if necessary. Do not rub
or brush the filter dry.
Let it dry completely prior to installation.
Illustration
I
 After that, insert the filter first and then
the frame.
 For appliances with ExPress filter
cleaning: Use the filter cleaning (see
Chapter "ExPress filter cleaning").
Note: If the suction performance is still
not satisfactory, in spite of the cleaning,
separate the suction hose from the
pipes, hold the opening of the suction
hose shut/close it and activate the filter
cleaning button three more times with
the suction hose held shut.
Troubleshooting
Mains cable retraction does not
 The mains cable is probably dirty, clean
the mains cable.
Water is leaking
 Turn off the appliance immediately.
J
Illustration
 Clean the floater system.
Remove the appliance head, unscrew the
floater basket (A) in the direction of the ar-
row and remove it. Remove the floater (B)
and clean both under flowing water.
If necessary, also clean the cover for
the floater valve (C): For this, release
and remove the cover. Reattach after
the cleaning process and lock it (ob-
serve the markings and symbols).
To install, first insert the floater, then
add the floater basket and lock it.