3.1.2 Selection of Installation Location
①.
If the outdoor unit will be exposed in strong wind, it must be securely located,
otherwise it may fall down.
②.
Install the air conditioner at a place where the inclination is less than 5° .
③.
Do not install the unit at a place with direct sunlight.
④.
Do not install the unit at a place with leakage of inflammable gas.
Selection of Installation Location for Indoor Unit (Select a location
pursuant to the following condition)
(1) Air inlet and outlet of the indoor unit should be away from obstacles to make
sure the unit's air flow can reach the entire room. Do not install the unit in a
kitchen or a laundry.
(2) Install the unit in a room without naked flame, fire source or the risk of getting
the refrigerant on fire.
(3) Select a location that can withstand 4 times the unit weight without increasing
operating noise and vibration.
(4) The installation location must be level.
(5) The indoor piping length and wiring length should be within the allowable range.
(6) Select a place that can easily drain condensate and connect to the drain system
of the air conditioner.
(7) If hoisting screw bolts are to be used, check whether the installation location is
safe enough. If not safe, reinforce the location before installation.
(8) Indoor unit, power cord, connecting wires and communication cords should be
at least 1m from television and radio. This is to prevent image interference or
noise (Even at a distance of 1m, a very strong electric wave may still generate
noise).
Selection of Installation Location for Outdoor Unit (Select a location
pursuant to the following condition)
(1) Noise and air flow produced by the outdoor unit will not disturb the neighbors.
(2) Select a location that is safe and away from animals and plants. If not, please
add safety fences to protect the unit.
(3) Install at a place with good ventilation. Make sure the outdoor unit stays at a
well-ventilated place with no obstacles nearby that may obstruct the air inlet and
outlet.
DC Inverter U-match Series Floor Ceiling Type Unit
WARNING
9