Multiple PLP-REM-300 installation
For extended installations (total lamp power > 300VA), multiple PLP-REM-
300's can be linked together. This way, a perfect synchronisation of all pool
lights is still guaranteed.
The PLP-REM-300's need to communicate with each other, to ensure all
the lamps are in perfect sync.
Connect the PLP-REM-300's with each other using the CAN bus:
Connect the CAN terminals of the first PLP-REM-300 with the CAN terminal
of the second PLP-REM-300*.
If more than 2 PLP-REM-300's are necessary, simply daisy chain each CAN
terminal with the one from the next PLP-REM-300 (see below).
Respect the polarity of the terminals! (CAN L & H)
Next, set the DIP switches on the PLP-REM-300's to the correct MASTER/
SLAVE setting. The first PLP-REM-300 will be the MASTER. All the others will
be SLAVE's. Refer to page 9 for Master/Slave DIP switch info.
In a Master/Slave setup, only the PLP-REM-300 that is set as MASTER
!
will react to transmitter commands. Any additional transmitters will
need to be paired with this MASTER PLP-REM-300
set as MASTER
230VAC
* We recommend using a shielded twisted pair cable (min. 0,5mm² - up to 200m) to connect
multiple PLP-REM-300's using the CAN bus.
set as SLAVE
CAN BUS
230VAC
set as SLAVE
230VAC