Troubleshooting Guide; Options And Accessories - Hatco Glo-Ray GRFHS Série Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING GUIDE

WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Symptom
Unit is on, but there is no
heat.
Unit is on, but there is no
lights.
Heat is inadequate.
Heat is excessive.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at www.hatcocorp.com, select the Support pull-
down menu, and click on "Find A Service Agent"; or contact the Hatco Parts and Service Team at:
Telephone: 800-558-0607 or 414-671-6350
e-mail:
support@hatcocorp.com

OPTIONS AND ACCESSORIES

GRFHS-PT26 w/ 6" (152 mm) Base
The GRFHS-PT26 is available with a 6" (152 mm) deep base
instead of the standard 4" (102 mm) base.
Chef LED Bulbs
Chef LED bulbs are available for all Fry Holding Stations.
CHEF LED bulbs are LED light bulbs that offer energy savings
over incandescent bulbs.
Probable Cause
No power to the unit.
Switch is defective.
Faulty wiring.
Heating element(s) are defective.
Light bulbs are loose or defective.
Excessive air movement around unit.
Incorrect power supply (low).
Internal base thermostat is set too low or is faulty.
Heating element(s) are defective.
Incorrect power supply (high).
Internal base thermostat is set too high or is faulty. Contact Authorized Service Agent or Hatco for assistance.
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
unplug power cord, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Corrective Action
Check circuit breaker and reset as necessary. If power cord
connected, check for damage to cord. If power cord connected,
check electrical receptacle.
Contact Authorized Service Agent or Hatco for assistance.
Tighten light bulbs. If light bulb is tight and still not working,
replace light bulb.
Restrict or redirect air movement (air conditioning duct or
exhaust fan) away from unit.
Check power supply to unit, making sure it matches rating on
the unit. If power supply is incorrect, change to match rating
on unit.
Contact Authorized Service Agent or Hatco for assistance.
Check power supply to unit, making sure it matches rating on
the unit. If power supply is incorrect, change to match rating
on unit.
Dividers
Additional dividers are available as accessories. Order using
the following Hatco P/N that corresponds to the appropriate
model.
Model
GRFHS-16,
GRFHS-26,
GRFHS-PT16................................................. FHSDIV1
GRFHS-21...................................................... FHSDIV2
GRFHS-PT26 (standard), GRFHS-PTT21...... FHSDIV3
GRFHS-22...................................................... FHSDIV4
GRFHS-PT26 (optional 6" [152 mm] Base).... FHSDIV5
GRFHS-PTT16................................................ FHSDIV6
8
English
WARNING
Order Number
Form No. GRFHSM-1020

Publicité

Chapitres

Table des Matières
loading

Table des Matières