2.4 technical installation

2.4.1 Parts

All filters and pumps must comply with the NF C15-100 installa-
tion standard, which stipulates that any electrical device within
a radius of 3 .50 m around the swimming pool and freely acces-
sible must be equipped with 12V low-voltage current .
Every electrical device of 220V must be placed at a minimum
of 3 .50 m from the swimming pool . For each change to one
or more elements of the filter kit, ask the advice of your
manufacturer . Also follow the instructions in the enclosed filter
installation manual .
The pump capacity
CRISTAL�FLO™ FILTRATION SYSTEM
type
OCTOO 4,00 / H120
OCTOO 4,20 / H120
OCTOO 4,20 / H133
OCTOO 5,00 / H120
OCTOO 5,00 / H133
OCTOO 6,25 / H133
7
10
8
9
6
2
4
5
3
52
Volume
Flow rate
KW
of water
9,11 m
6 m³/h
0,25
3
10,53 m
3
6 m³/h
0,25
11,86 m
6 m³/h
0,25
3
15,44 m
8 m³/h
0,37
3
17 ,39 m
8 m³/h
0,37
3
27 ,99 m
12 m³/h
0,55
3
The monobloc filter is the device that is responsible for water
treatment . Filter, pump and six-way valve are collected in one
device . The most important parts of the filter unit are: the filter,
the pump, six-way diverter valve, emptying cap, mains cable,
connecting line .
the pump must never be more than 4 meters higher than
the filter inlet and must be placed in a dry room.
The pump must be inspected annually to ensure proper
operation .
Ø sandfilter
option
elektr. box
350 mm
34001
code
350 mm
34001
code
350 mm
34001
code
450 mm
34002
code
450 mm
34002
code
550 mm
34003
code
13
11
12
1
1 . Base plate
2 . Filtration tank
3 . Drain
4 . PVC pipe
5 . Spray head
6 . Sand guide
7 . 6-way shutter
8 . Rubber
9 . Metal Clamping Band
10 . Pressure gauge
11 . Pump
12 . Bolts + nuts for pump
13 . Tube