Télécharger Imprimer la page

Key Automation SN-50 Instructions Et Avertissements Pour L'installation Et L'usage page 10

Motoréducteur pour portails à battants

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
EN
2 - PRODUCT OVERVIEW
2.1 - Description of the product
The MEWA gear motors are destined to be installed in systems for
the automation of gates with hinged doors.
The MEWA gear motors have been designed and constructed to be
fitted onto hinged doors within the weight limits indicated in the
2.2 - Model and technical characteristics
Code
Description
SN-50
Articulated arm electromechanical irreversible gear motor for sash opening, 230 Vac.
Articulated arm electromechanical irreversible gear motor for sash opening, 24 Vdc, with already assembled opening and
SN-50-24
closing switch limit. Intensive use.
TECHNICAL DATA
MODELS
TECHNICAL SPECIFICATIONS
Torque
Working cycle
Opening time at 90°
Control board
Power supply
Absorption
Engine power
Capacitor
Thermoprotection
Degree of protection
Dimensions (L - P - H)
Weight
Operating temperature
Leaves maximum weight
3 - PRELIMINARY CHECKS
Before installing this product, verify and check the following steps:
- Check that the gate or door are suitable for automation
- The weight and size of the gate or door must be within the maxi-
mum permissible operating limits specified in Fig. 2
- Check the presence and strength of the security mechanical stops
of the gate or door
- Check that the mounting area of the product is not subject to flood-
ing
- Conditions of high acidity or salinity or proximity to heat sources
could cause malfunction of the product
- Extreme weather conditions (for example the presence of snow,
ice, high temperature range, high temperatures) may increase the
friction and therefore the force required for the handling and initial
starting point may be higher than under normal conditions.
10
technical specifications table.
The use of gear motors for applications which differ from those
indicated above is prohibited.
Nm
%
sec
Vac (Vdc)
A
W
µF
°C
IP
mm
330 - 187 - 157
Kg
°C
Kg
- Check that the manual operation of gate or door is smooth and
friction-free and there is no risk of derailment of the same
- Check that the gate or door are in equilibrium and stationary if left
in any position
- Check that the power line to supply the product is equipped with
proper grounding safety and protected by a magnetothermal and
differential security device
- Provide the power system with a disconnecting device with a gap
of contacts enabling full disconnection under the conditions dictated
by the overvoltage category III.
- Ensure that all materials used for the installation comply with cur-
rent regulations
SN-50
400
30
18
CT202
230
1,5
340
12
150
43
14
-20°+55°
800
SN-50-24
350
80
adjustable
14AB2
(24)
5
120
-
-
43
330 - 187 - 157
13,8
-20°+55°
400

Publicité

loading

Ce manuel est également adapté pour:

Sn-50-24