Applicable controls
REQUIREMENT
When the unit is used for the first time, it takes a while
for the remote controller to recognize operation input
after the power is turned on. This is not a malfunction.
Turning on the power the fi rst time after
installation
It takes approximately 10 minutes until you can
operate the remote controller.
About 10 minutes
Power on
"    " blinks
"    " turns off
Turning on the power from the 2nd time onward
It takes approximately 3 minutes until you can operate
the remote controller.
About 3 minutes
Power on
"    " blinks
"    " turns off
• Normal settings were made when the indoor unit
was shipped from factory.
Change the indoor unit settings as required.
• Use the built-in remote controller to change the
settings.
* The settings cannot be changed using the
wireless remote controller, simplifi ed wired
remote controller, or remote-controller-less
system (for central remote controller only).
41-EN
Basic procedure for changing
settings
Change the settings while the air conditioner is not
working. (Stop the air conditioner before making
settings.)
The display content for setting differs from that on the
former types of remote controller (RBC-AWSU52-UL)
Remote
CAUTION
controller
can be used
Set only the "Code(DN)" shown in the following table:
Do not set any other "Code(DN)".
If a "Code(DN)" not listed is set, it may not be possible
to operate the air conditioner or other trouble with the
product may result.
Remote
controller
can be used
1
In the "Field setting menu" screen, press
[ 
 ] and [ 
 ] to select "DN setting", and
then press [ 
Set/Fix]
2
Press [ 
 ] and [ 
 ] to select
"Indoor unit" or "Outdoor unit", and the
press [ 
Set/Fix]
If "Indoor unit" was selected, the fans and

louvers of the indoor units operate.
When doing group connections:
The fans and louvers of the selected indoor

units operate.
– 21 –
3
Press [ 
 ] to black highlight the item code
(DN), and then press [ 
 ] and [ 
 ] to set
the item code
4
Press [ 
 ] to black highlight the data, and
then press [ 
 ] and [ 
 ] to set the data
5
After finishing setting the data of the item
code (DN), press [ 
Set/Fix]
"Continue?" is displayed.

6
To set the data of other item codes (DN),
press [ 
Set/Fix]
To not do other settings, press [ 
Return]
The changes are fixed, and the "Field setting

menu" screen returns.
"   " appears while data is changing.

When doing group connections:
Press [ 
Return] to open the unit selection

screen. In the unit selection screen, press
[ 
Return] to briefly display "   ", and then
return to the "Field setting menu" screen.
42-EN