en-us Conversion to LP gas
Double burner, first orifice
Double burner, second orifice
It is important to make sure that the orifices do not be-
come detached during removal or fastening.
They must be properly tightened to ensure that there
are no leaks.
The primary air does not have to be adjusted.
Fasten the orifices and replace the burner caps to the
3.
corresponding burners.
Put the burner grates in place.
4.
Save the orifices removed from the appliance for future
5.
use.
5.4 Burner chart
Refer to this overview for specifications of the individual burners.
Burner
Gas type
cap
Small
Natural gas
burner
Propane gas
Large
Natural gas
burner
Propane gas
Medium
Natural gas
burner
Propane gas
14
Pressure
Orifice
in inch
wc
6
77
10
54
6
133
10
93
6
102
10
71
5.3 Adjusting the gas valves
Turn the control knobs to position 0.
1.
Carefully lift off the burner grates, remove the burner
2.
caps and the burner bases.
Pull off the control knobs.
3.
Remove the main top from the cooktop.
4.
Note: Do not remove the illuminated rings under any
circumstances. You will require Customer Service to re-
fit them.
Remove the electronics pack from the control panel.
5.
Remove the white disks from the valve stems.
6.
Adjust the black T10 star head setting screw with a T10
7.
star head screwdriver. Refer to the burner chart for the
correct setting of the setting screws (M).
→  "Burner chart", Page 14
Use setting
for LP Gas. The setting screws must
be tightened properly.
Use setting
for natural gas. The setting screws
must finish flush with the fitting.
The dual-flame burner has 2 setting screws.
Replace the white disks and the electronics pack.
8.
Reinstall the main top and the control knobs.
9.
Place the burner caps and the burner grates back in po-
10.
sition.
Turn the control knob between the highest and lowest
11.
setting. Make sure the flame does not go out and there
are no flashbacks.
Note: In the event of damage, the valve must be com-
pletely replaced.
BTU/h
kW
3,400
1.00
3,400
1.00
10,300
3.00
10,300
3.00
6,000
1.75
6,000
1.75
M (valve ad-