BLOWER
SPEED
0.2" (W.C.)
2130
HIGH
MED-HIGH
1930
1565
MED-LOW
1185
LOW
1
FURNACE
SIDES
PLENUM AND WARM-AIR DUCT WITHIN 6 ft. OF FURNACE
2
BOTTOM
FURNACE
BACK
FURNACE (OPPOSITE SIDE OF THE BURNER)
PLENUM OR HORIZONTAL WARM-AIR DUCT WITHIN 6 ft. OF FURNACE
TOP
2
FURNACE
FLUE PIPE
AROUND FLUE PIPE
FRONT
FURNACE (BURNER SIDE)
1
These are horizontal dimensions
2
These are vertical dimensions
3
This dimension can be obtained by using Horizontal Flow Base # HFB-101 or # KLASB0701DET
4
This dimension can be obtained by using Downflow Base # DFB-104 or # KLASB1001DET
Table 8 - Airflow data model with 1HP 4-speed motor
EXTERNAL STATIC PRESSURE WITH AIR FILTER
0.3" (W.C.)
0.4" (W.C.)
2085
1855
1495
1170
Table 9 - Minimum clearances from combustible materials
LOCATION
1
1
0.5" (W.C.)
1995
1915
1800
1750
1460
1430
1140
1105
1
2
45.72 cm (18")
16
0.6" (W.C.)
1820
1675
1400
1080
UPFLOW
HORIZONTAL
2.54 cm (1")
N/A
5.08 cm (2")
2.54 cm (1")
3
2.54 cm (1")
Ø
7.62 cm (3")
7.62 cm (3")
5.08 cm (2")
7.62 cm (3")
N/A
5.08 cm (2")
22.86 cm (9")
22.86 cm (9")
45.72 cm (18")
0.7" (W.C.)
1745
1615
1360
1065
DOWNFLOW
5.08 cm (2")
5.08 cm (2")
4
5.08 cm (2")
7.62 cm (3")
5.08 cm (2")
N/A
22.86 cm (9")
45.72 cm (18")