Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

154 Series, m ulti-position models
RATING AND PERFORMANCE
Firing rate (USGPH)*
Input (BTU/h)*
Maximum Heating capac it y, (BTU/h)*
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire press ure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c. - no wind)
Overfire press ure with direct vent (inch of w.c. - no wind)
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner t ube insertion length (inches)
Head type
Nozzle (Delavan)
Pump pressure (PSIG)*
Head/Air setting
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; MODEL 40-F5 (Chim ney)
Burner t ube insertion length (inches)
Nozzle (Delavan)
Pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
RIELLO BURNER; MODEL 40-BF5 (Direct vent DV)
Burner t ube insertion length (inches)
Nozzle (Delavan)
Pump pressure (PSIG)*
Combustion air adjustment (turbulator/damper)
AFUE % (From CSA B212 standard and Canadian regulation)**
AFUE % (From ASHRAE 103 standard and US regulation)**
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control t ransformer (VA)
External control power available
BLOWER DATA
Heating blower speed at 0.25" W.C. SP
Heating blower speed at 0.50" W.C. SP
Motor (HP) / number of speeds
Blower size (diam. x width)
GENERAL INFORMATION
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x dept h)
Filter size
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5" W.C. SP
* INPUT & OUTPUT ADJUSTMENT:
- Pump pressure can be adjusted to maintain proper firing rate.
- Increase pump pressure if flue gases temperature is under 400˚F
- Adjust the total flue gas temperature between 400˚ and 575˚F (330˚ and 505˚ F net approx.)
- Adjust fan speed for air temperature rise of 55˚ to 85˚F.
** AFUE value established after minimum 20 hours of operation.
Table 6 - Technical Specifications
Heating (VA)
Cooling (VA)
UNITS WITH 1.0 HP 4-SP. MOTOR
0.90
1.10
126 000
154 000
107 000
129 000
55 - 75 Degr. F
-0.06 to -0.035
-0.035 to +0.045
+0.05 to +0.16
+0.06 to +0.22
NX50LC
1 3/4''
6 Slots - LC head
0. 75 - 60B
0.90 - 60B
145
150
3.5
4
‡ 87,0%
‡ 85. 7%
‡ 86.6%
‡ 85, 2%
F5 WITH ELECTRIC AIR DAMPER
2 3/4''
0. 75 - 70A
0.90 - 70A
145
150
1.5 / 2.25
2.5 / 2.75
‡ 86.7%
‡ 85. 3%
‡ 86.3%
‡ 85, 0%
BF5
2 3/4''
0. 75 - 70A
0.90 - 70A
145
150
1.0 / 3.75
3.0 / 4.25
‡ 86.7%
‡ 85. 3%
‡ 86.3%
‡ 85, 0%
115 - 60 - 1
16.9
19.5
20
40
40
30
MED-LOW
MED-HIGH
MED-LOW
MED-HIGH
1.0 HP / 4 speeds
12'' x 10'' (tight housing)
25'' x 28 1/2'' x 48''
20'' x 22''
23'' x 23''
24'' x 24'' x 1"
200 / 90
5.0
14
UNITS WITH 1.0 HP ECM MOTOR
0.90
1.10
126 000
154 000
107 000
129 000
60 - 72 Degr. F
-0.06 to -0.035
-0.035 to +0.045
+0.05 to +0.16
+0.06 to +0.22
NX50LC
1 3/4''
6 Slots - LC head
0.75 - 60B
0.90 - 60B
145
150
3.5
4
‡ 87,0%
‡ 85.7%
‡ 86.6%
‡ 85,2%
F5 WITH ELECTRIC AIR DAMPER
2 3/4''
0.75 - 70A
0.90 - 70A
145
150
1.5 / 2.25
2.5 / 2.75
‡ 86.7%
‡ 85.3%
‡ 86.3%
‡ 85,0%
BF5
2 3/4''
0.75 - 70A
0.90 - 70A
145
150
1.0 / 3.75
3.0 / 4.25
‡ 86.7%
‡ 85.3%
‡ 86.3%
‡ 85,0%
115 - 60 - 1
15.7
18.1
20
40
40
30
See the ECM air flow table
1. 0 HP / ECM (with inductor)
12'' x 10'' (tight housing)
25'' x 28 1/2'' x 48''
20'' x 22''
23'' x 23''
24'' x 24'' x 1"
200 / 90
5.0
‡ =