GENERAL
Gas fired broilers are designed for commercial
use only and feature fast, efficient gas heat.
Each burner is controlled by an adjustable
on/off gas valve.
Model
Number
of Burners
VST4B
3 @ 45,000 ea.
UNPACKING
Immediately after unpacking, check for
possible shipping damage. If the broiler is
found to be damaged, save the packaging
material and contact the carrier within 15
days of delivery.
INSTALLATION
Before installing, verify that the type of gas
(natural or propane) and the clearance
dimensions (see below) agree with the
specifications on the rating plate which is
located on right hand side of unit.
Location
The installation location must be kept free and
clear of combustibles. Do not obstruct the
flow of combustion and ventilation air.
Clearances
Check that there are sufficient clearances to
service the broiler and to make the required
gas supply connection(s). Provide 24"
clearance at the front for cleaning,
maintenance, service and proper operation.
All manuals and user guides at all-guides.com
INTRODUCTION
BTU/hr Input
Rating
135,000
— 4 —
Combustible
Construction
Sides
Rear
6 inches 6 inches
INSTALLATION CODES
AND STANDARDS
The broiler must be installed in accordance
with the following:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1/
NFPA #54 (latest edition). Copies may be
obtained from The American Gas
Association
Accredited
Committee Z223, @ 400 N. Capital St. NW,
Washington, DC 20001, or the Secretary
Standards Council, NFPA, 1 Batterymarch
Park Quincy, MA 02169-7471.
3. NFPA Standard #96 Vapor Removal from
Cooking Equipment, latest edition,
available from the National Fire Protection
Association, Batterymarch Park, Quincy,
MA 02269.
4. In the Commonwealth of Massachusetts all
gas appliances vented through a ventilation
hood or exhaust system equipped with a
damper or with a power means of exhaust
shall comply with 248 CMR.
In Canada:
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation
(latest edition).
3. CAN/CSA-B149.2 Propane Installation Code
(latest edition), available from the Canadian
Gas Association, 178 Rexdale Blvd.,
Etobicoke, Ontario, Canada M9W 1R3.
Non-Combustible
Construction
Sides
Rear
0 inches
0 inches
Standards