Parameter Type
Description
1
Setting
Temp Display As C/F
2
Setting
Liquid Level Display As Inches/cm
3
Setting
Extra High Level
4
Setting
Temp Control
5
Setting
Output Signal Type
6
Setting
Fill Timer
7
Setting
Bypass Option
10001
Status
Fill Valve Status
10002
Status
Bypass Valve Status
10003
Status
Alarm Relay Status
10004
Status
Sequential Input Signal
10005
Status
Sequential Output Signal
10006
Status
Lid Open Status
10007
Status
Bypass Open
10008
Status
Fill Valve Open
10009
Alarm
Low Level Alarm
10010
Alarm
High Level Alarm
10011
Alarm
Source Alarm
10012
Status
Mute
10013
Status
Buzzer
10014
Alarm
Open TC Probe-A
10015
Alarm
Open TC Probe-B
10016
Alarm
Open Probe-Bypass
10017
Alarm
LidTemp-A Alarm
10018
Alarm
LidTemp-B Alarm
30001
Current Reading
Liquid Level
30002
Current Reading
Temp-A
30003
Current Reading
Temp-B
30004
Current Reading
Bypass Temp
40001
Setting
High Level Setting
40002
Setting
Low Level Setting
40003
Setting
High Temp Setting
40004
Setting
Low Temp Setting
40005
Setting
Temp-A Setting
40006
Setting
Temp-B Setting
40007
Setting
High Alarm Setting
40008
Setting
Low Alarm Setting
40009
Setting
Source Alarm Timer
40010
Setting
Temp Control Setpoint
40011
Setting
Tank ID Value
40012
Setting
Fill Timer Interval
40013
Setting
Fill Start Time: Hours
40014
Setting
Fill Start Time: Minutes
40015
Setting
Clock: Date Value
40016
Setting
Clock: Month Value
40017
Setting
Clock: Year Value
40018
Setting
Clock: Hours Value
40019
Setting
Clock: Minutes Value
40020
Setting
Clock: Seconds Value
40021
Setting
Bypass Threshold Value
40022
Setting
Bypass Kickpoint Temp Value
40023
Setting
Ignore Overflow Period Set
40024
Setting
OneFill AllFill Option(OFAF)
40025
Setting
OFAF Timer
40026
Setting
Sequential Fill Relay Timer Set
40027
Setting
Fill Value Threshold
40028
Setting
Report Interval
40029
Setting
Temp Print Interval
40030
Setting
Log Interval
40031
Setting
LN2 Overflow
40032
Setting
LN2 Overflow Ignore Timer Run
40033
Setting
Lid Open Alarm Timer Set
40034
Setting
Lid Open Alarm Timer Run
40035
Setting
DHCP Option
40036:39
Setting
IP Address
40040:43
Setting
Subnet Mask
40044:47
Setting
Gateway Address
40048:51
Setting
DNS Address
ES-CSS-IFU002
Mode d'emploi – Systèmes de cryoconservation
Original
Modbus Variants list
Value / (unit)
0:F 1:C
0:Inches 1:Centimeters
1:Enabled 0:Disabled
1:Enabled 0:Disabled
1:0-5V 0:4-20mA
1:Enabled 0:Disabled
1:Enabled 0:Disabled
0:Closed 1:Open
0:Closed 1:Open
0:Off 1:On
0:Off 1:On
0:Off 1:On
0:Closed 1:Open
0:Yes 1:No
0:Yes 1:No
0:Off 1:On
0:Off 1:On
0:Off 1:On
0:Off 1:On
0:Off 1:On
0:Off 1:On
0:Off 1:On
0:Off 1:On
0:Off 1:On
0:Off 1:On
Inches/Centimeters
C/F
C/F
C/F
Inches/Centimeters
Inches/Centimeters
C/F Value
C/F Value
C/F Value
C/F Value
Minutes
Minutes
Minutes
C/F Value
24Hrs/48Hrs/72Hrs
0-23Hrs
0-59
1-31
1-12
00-99
0-12
0-59
0-59
200 to 3000
Temp Value Deg C or F
Units are count of minutes
0:Disabled 1:Simultaneous 2:Sequential
In Hours
In Seconds
200 to 3000
In Days
In Hours
In Hours
0:Disabled 1:Enabled 2:Ignore Current Overflow
Condition
Remaining Running Timer Value in Seconds
0-300 sec
Timer Counting
0:Static 1:Enabled
4 bytes
4 bytes
4 bytes
4 bytes
Page 37 sur 43
Function Number
Data Class
Read Coil
Function 1,Read Only :
Bits
Function 5,15 Write
Read Input Status
BI
Function 2 , Read Only
Function 4, Read Input
Process Input
Register Value
Value (Read Only)
Function3 Read Only,
AV
Function 6,16 Write