Télécharger Imprimer la page

Eco-Flo EFSWJ5 Manuel Du Propriétaire page 6

Publicité

Les langues disponibles

Les langues disponibles

Convertible
Jet Pump
A Convertible Jet Pump can be used either in shallow well applications, (0-25') or in deep well ap-
plications, (26' to 75'). Both measurements are from the intake port of the pump to the height of
the endd of the suction pipe. The pump can be converted shallow to deep or deep to shallow.
When properly installed your jet pump should provide the following performance:
Preparing the Convertible Jet Pump for Shallow
Well Application
1. Note the nozzle is used in both shallow well and deep
well applications and is installed in the ejector casting at
the factory (Fig. A).
2. The nozzle should be finger tight and one quarter of a
turn more using a wrench or a pair of pliers.
3. Select the venturi tube marked with the horsepower of
your pump motor, i.e. 1/2HP or 3/4HP etc, or marked
with "SW' denoting for shallow well applications.
4. Install the venturi tube in the ejector housing. (Fig. A)
For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561
All manuals and user guides at all-guides.com
CONVERTIBLE WELL PUMP INSTALLATIONS
SHALLOW WELL FOR 4" DIAMETER WELL APPLICATION- PUMP PERFORMANCE*
PRESSURE
MOTOR
MODEL
HP
VOLTAGE
EFCWJ5
1/2 115/230
EFCWJ7
3/4 115/230
EFCWJ10
1
115/230
* Performance shown in GPM (gallons per minute) at 40 PSI (pounds per square inch) discharge pressure.
DEEP WELL FOR 4" DIAMETER WELL APPLICATION- PUMP PERFORMANCE*
PRESSURE
MOTOR
MODEL
HP
VOLTAGE
SETTINGS
EFCWJ5
1/2 115/230
EFCWJ7
3/4 115/230
EFCWJ10
1
115/230
* Performance shown in GPM (gallons per minute) at 40 PSI (pounds per square inch) discharge pressure.
(Fig. A)
Ejector
Casting
DISTANCE PUMP ABOVE WATER
SWITCH
5'
10'
15'
20'
SETTINGS
GALLONS PER MINUTE PUMPED
30-50
6.4
5.4
5.2
4.5
30-50
10.1 9.1
8.3
7.5
30-50
14.8 12.0 10.8
9
DISTANCE PUMP ABOVE WATER
SWITCH
20'
30'
40'
50'
GALLONS PER MINUTE PUMPED
30-50
4.5
3.5
2.8
2.3
30-50
7.5
6.5
5.1
4.0
30-50
9.0
8.4
7.3
6.2
5. Tighten the venturi tube in the casting finger
tight and one quarter additional turn with
wrench or pair of pliers.
6. Mount the ejector on to the convertible well pump
placing the gasket between the ejector and the
jet pump's body (Fig. B).
7. Secure the ejector to the
pump body with the bolts
provided with the ejector kit.
8. Ensure the bolts are tight.
9. You have now completed
assembling the convertible jet
pump for shallow well applications.
10. Install the pump and the balance of the pump
accessories, i.e. tees, gauges, etc by following
instructions associated with figures 1, 2, and 3.
6
Shallow & Deep Well
Venturi Tubes
Ejector
Gasket
Mounting
Nozzle
Bolts
PRESSURE
25'
SHUT-OFF AT
MAX. DEPTH
4
57 PSI
7.0
56 PSI
8.7
60 PSI
PRESSURE
60'
70'
SHUT-OFF AT
MAX. DEPTH
1.7
-
54 PSI
3.0
2.5
56 PSI
5.0
4.4
56 PSI
(Fig. B

Publicité