Gas regulator valve
Cap
Nut
Jet pressure adjustment
Make sure that the maximum pressure is set first. Else the minimum pressure would be
changed by turning the nut.
Loosen the locking bolts of the connection pressure and jet pressure measuring stub.
Check the connection pressure and jet pressure.
Remove the cap from the pressure regulator.
Fit a socket wrench or a ringspanner to the nut of the pressure regulator.
Setting maximum pressure at full heating
Values for natural gas: see table "Settings with natural gas"; values for liquid gas: see table
"Settings with liquid propane"
To increase or reduce the maximum jet pressure turn the nut in a clockwise or counter-
clockwise direction.
Adjusting the minimum pressure with power supply interrupted
Pull out the plug. You need a slotted Screwdriver to adjust the minimum pressure.
To increase or reduce the minimum jet pressure turn the slotted screw inside the nut in a
clockwise or counterclockwise direction.
Make sure that the nut does not turn with it.
Insert the plug again.
Fit the cap onto the pressure regulator.
Seal the connection pressure and jet pressure measuring stubs with the locking bolts.
Electrical plug
en - Installation notes
Connection pressure
measuring stub
Pressure regulator