7 DAY PROGRAMMABLE HYDRONIC THERMOSTAT
GUIDELINES
TURN OFF POWER TO THE HEATING SYSTEM AT
THE MAIN POWER PANEL TO AVOID ELECTRICAL
SHOCK. INSTALLATION SHOULD BE CARRIED OUT
BY AN ELECTRICIAN.
• For a new installation, choose a location about 5 ft.
(1.5 m) above the floor.
• The thermostat must be installed on an inside wall.
• Avoid locations where there are air drafts (top of
staircase, air outlet), dead air spots (behind a door),
direct sunlight, or concealed chimneys or stove pipes.
PROCEDURE
1. Loosen the captive screw securing the front mod-
ule to the rear module as shown in Fig. 1.
2. Lift the lower part of the front module to remove it
from the rear module.
3. Loosen the captive screw holding the terminal
cover and remove the cover.
4. Pass the wires through the opening to the right of
the terminals. See Fig. 2. Secure the rear module
to an electrical box or to the wall using the supplied
wall anchors and screws.
5. Connect the wires (see section "Thermostat Wir-
ing" on page 2). Use 12 AWG or smaller wire. 14
AWG is recommended for line voltage, 18 AWG is
recommended for 24 VAC.
6. Install the terminal cover and tighten the screw.
7. Configure the thermostat using the switches
located on the back of the front module (see sec-
tion "Thermostat Configuration" on page 3).
8. Install the batteries (see section "Power-up" on
page 3).
9. Mount the front module onto the rear module and
tighten the screw.
INSTALLATION INSTRUCTIONS
1
2
4
5
8
7
Fig. 1. Installation steps.
Fig. 2. Routing wires to thermostat.
3
6
9
M29963
SUPPLY
LOAD
PROVIDED
WIRES
M29964
Table des Matières
loading

Sommaire des Matières pour Honeywell TL8100

  • Page 5: Comment Faire

    TL8100 THERMOSTAT HYDRONIQUE PROGRAMMABLE NOTICE D'INSTALLATION DIRECTIVES COUPER L'ALIMENTATION ÉLECTRIQUE DU SYSTÈME DE CHAUFFAGE AU TABLEAU PRINCIPAL POUR ÉVITER TOUT CHOC ÉLECTRIQUE. IL EST PRÉFÉRABLE DE CONFIER L'INSTALLATION À UN ÉLECTRICIEN. • S'il s'agit d'une nouvelle installation, choisir un emplacement à environ 1,5 m (5 pi) du sol.
  • Page 6: Raccordement Du Thermostat

    TL8100 RACCORDEMENT DU THERMOSTAT V8043F TH, TR TH TR TL8100 120 V c.a. OU 240 V c.a. CHARGE INDUCTIVE DE 2 A MAX. M29978 TL8100 MF29965 Fig. 14. Schéma de câblage pour un circulateur sur Fig. 19. Schéma de câblage d'une vanne de 24 V c.a.
  • Page 7: Configuration Du Thermostat

    TL8100 CONFIGURATION DU • Lorsque plus d'un TL8100 est directement câblé à une vanne de zone ou un circulateur de zone. THERMOSTAT Voir le Table 6 pour régler les interrupteurs n° 1 et 2 au mode conventionnel. Le Table 4 illustre la configuration des interrupteurs au dos du module avant.
  • Page 8 TL8100 Solutions de régulation et d’automatisation Honeywell International Inc. 1985 Douglas Drive North ® Marque de commerce déposée aux États-Unis © 2012 Honeywell International Inc. Golden Valley, MN 55422 Tous droits réservés 69-2017EFS—03 L.L. Rev. 03-12 customer.honeywell.com Imprimé aux États-Unis...

Table des Matières