electrical connection
1. Route the power cord to the junction box inside the hood.
2. Using listed conduit fittings and connectors, connect the power supply to the box and each
line to the appropriate wire following this color convention:
BLACK = HOT LEG
WHITE = NEUTRAL
GREEN/YELLOW = GROUND
Polarity must be observed.
Unit must be properly grounded.
Use a double throw disconnect switch.
3. Replace the box cover
4. Replace the Anti-grease Baffles.
All wiring must be in compliance with national electrical code, ANSI/NFPA 70-1999 and all
local codes and regulations.
WARNING - Suitable for use in damp location when installed in a GFCI protected branch circuit.