Télécharger Imprimer la page

Aritech AS280 Guide Rapide page 2

Publicité

Les langues disponibles

Les langues disponibles

Installation and set-up
1.
Remove sounder cover.
2.
Pass wires from control panel through the opening at the
rear of the sounder
3.
Fix back plate to wall with screws through mounting slots.
Fix a screw in the wall at correct position to operate the
tamper if sounder is removed from mounting.
4.
Connect terminals +ALIM and 0V ALIM respectively to the
14.3 V and 0 V supply from control panel.
5.
Connect the terminals to the tamper circuit of the control
panel.
IMPORTANT – In positioning the battery, make sure the
6.
terminals are placed towards the front of the sounder. See
drawing on next page.
7.
Connect the battery observing correct polarity. Battery
NP2.1 or PS-1221, 12 V, 2.1 Ah
8.
Connect the terminal +BL to the sounder output of the
control panel (+V hold off).
9.
NB: During power up, the siren is not active until +BL is
taken to < 3.2 V.
Testing
Put the jumper in place at « 5 seconds test ». Activate the
1.
sounder output at the control panel (+BL to 0 V or
floating). Check the siren operates.
2.
Open the cover. Make sure the control panel detects the
tamper.
Remove the jumper « 5 seconds test ». Adjust the timer to
3.
15 or 30 minutes.
4.
Replace sounder cover and fasten cover screw. Make
sure the tamper is not activated (closed contact).
IMPORTANT:
The jumper must be placed for a maximum
duration of 30 min.
IMPORTANT:
The battery must be a NP2.1 or PS-1221.
Dispose of used batteries in accordance with all national and
local regulations.
2 / 4
Battery
Speaker
Tamper
+V hold off
Supply
Specifications
116 (±2) dBA at 1 m
Sound output
Operating voltage
9 to 15 VDC
Voltage +ALIM
14.3 VDC
Maximum supply
350 mV
voltage ripple
Max current +ALIM
100 mA (including recharging of battery)
Hold off voltage +BL
Activation of siren is < 3.2 V
Silent if > 8.1 V
250 μA
Trigger current +BL
Battery
12 V, 2.1 Ah lead acid ref. NP2.1 YUASA
12 V, 2.1 Ah lead acid ref. PS-1221
PowerSonic
Type of cable
6 or 8 cores (0,22mm
functions used
9.0 V min – 10.0 V max typical
Battery discharge cut-
off protection
Battery recharge time
<24 hours after 30 minutes of activation
Current – battery
1.3 A max for full alarm
5 mA standby (not including battery charging)
Current – control panel 100 mA max (including battery charging)
Cut off timer
15 or 30 minutes and 5 seconds in test mode
13.8 – 15 VDC, limit at 100 mA (14.3 V
Operating voltage for
battery charging
nominal)
External dimensions
92 x 183 x 55 mm
Operating temperature −10 to 55°C
Weight
1.6 kg
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
P/N 466-2979 (ML) • REV C • ISS 22JUL21
Jumper
5 sec test
Cut off timer jumper
Off = 15 min
On = 30 min
2
) depending on

Publicité