Electrical Installation - Bosch 500 Benchmark Serie Manuel D'installation

Masquer les pouces Voir aussi pour 500 Benchmark Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8. RefertotheElectrical Connection s ection forfurther
information t ocomplete t heelectrical connection ofthe
combination u nittothemainpower supply.
Electrical
Installation
All model ovens on the front cover of this installation
instruction manual are dual rated, designed to be
connected to either 208 or 240V AC, 60 Hz, 4 wire, single-
phase power supply.
Model
Circuit Required
208V, 60 Hz
240V, 60 Hz
HBN54, HBN84,
HBL53, HBL54,
30 AMP
HBL84, HBLP4
HBL55
30 AMP
/
40 AMP
[
HBN56, HBL56,
HBL57, HBN86,
HBL86, HBL87,
HBLP6, HBLP7,
HSLP7
40 AMP
Four-wire Connection
Ungrounded Neutral
power supply
junction
box
red wires
green or bare
wire
green wire
UL listed
connector
black wires
white wires
cable from
oven
Connect the red oven wire to the red electrical supply
wire (hot wire).
Connect the black oven wire to the black electrical
supply wire (hot wire).
Connect the white neutral oven wire to the white
neutral (not bare or green ground) electrical supply
wire.
Connect the green ground oven wire to the bare or
green ground electrical supply wire.
Three-wire Connection
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized,
UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
Important: Local Codes may vary; installation, electrical
connections and grounding must comply with all applicable
local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and the
green ground wire from the oven to the white neutral
electrical supply wire.
Important: If you have purchased a combination oven unit
(one that includes a microwave or steam oven over the
single oven), see the preceding section "Connecting the
Microwave Oven or Steam Oven Electrical Conduit to the
Single Oven" showing electrical connection of the
combination unit components.
WARNING
Grounded Neutral
power supply
junction
box
.
red wires
_2_,
white,
bare, or
green wire
white wire
green
wire
black wires
UL listed
connector
cable from
oven
Connect red wire from oven to red wire in junction box.
Connect black wire from oven to black wire in junction
box.
Connect both green ground wire and white wire from
oven to white, green or bare neutral wire in junction
box.
The conduit cable, where connected at the oven, swivels.
Rotate conduit cable upward (or downward) and direct
through hole prepared in cabinet to attach to J-Box.
Complete the connection of the microwave or steam
oven conduit to the single oven before proceeding
with the unit electrical connection to the main power
supply.
To maintain serviceability, the flex conduit must not be
shortened and should be routed to permit temporary
removal of the oven.
Electrical Connection to Main Power Supply
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also acceptable.
English 8
9000989321 Rev A

Publicité

Table des Matières
loading

Table des Matières