Figure 8 - FT-X Minimum Required Fall Clearance for 310 to 420 lbs. (141 to 191 kg) Users
2
6.0 Maintenance, Service, and Storage
6.1 Maintenance:
Ensure the SRL is kept free of excess paint, grease, dirt or other contaminants as this may cause
the lifeline or retracting mechanism to malfunction. Ensure no debris enters the housing. Clean the
exterior of the unit as required with a detergent/water solution. Do not allow water or other corrosion
causing elements to enter the housing. After cleaning, pull the lifeline all the way out, allow the unit to
air dry, then retract the lifeline into the unit. Clean labels as required.
DO NOT use heat to dry.
DO NOT attempt to disassemble the SRL.
6.2 Service:
Remove the unit from service if it has been subjected to fall arrest force. Tag the unit as "UNUSABLE" to
prevent future use. The SRD is not repairable.
6.3 Storage:
Store the FT-X Web in a cool, dry, clean environment out of direct sunlight. Position the SRL so excess
water can drain out. Avoid exposure to chemical or caustic vapors. Thoroughly inspect the SRL after
any period of extended storage.
13
1
1 foot (0.3 m)
increments along the
X-Axis represents the
Horizontal Distance
to Anchorage the
user is working away
from the SRD
Example 1:
If the user is working 3 feet (0.9 m) away from the
SRD, and the SRD is anchored between 1 ft (0.3
m) below the user's Dorsal D-Ring or up to 3 ft
(1.1 m) above the D-Ring. Minimum required fall
clearance is 10 feet (3.0 m) including swing fall.
Example 2:
If the user needs to work 4 feet (1.2 m) away
from the SRD along the edge, and the SRD at
the maximum 3 ft (1.1 m) below the D-ring, the
minimum required fall clearance is 17 feet (5.2 m)
including swing fall.
1 foot (0.3 m)
increments up the Y-Axis
represent the Elevation
of the Anchorage from
the user's Dorsal D-Ring