7.0 Inspection
7.1 Pre-Use User Inspection:
Perform an inspection before each use in accordance with the recommendations in Table 1 below.
Inspection
The web lifeline should extract and retract completely and without faltering and should
remain taut under tension without sagging.
Extract the web lifeline several inches and apply a firm pull to confirm the SRD locks. The
locking should be certain and without skidding. Repeat this lockup at additional places along
the lifeline length to confirm the SRD is operating correctly.
Examine the energy absorber on the lifeline to be certain that it has not been activated.
Review the web lifeline closely for wear created by abrasion, tattered yarns, unraveled
strands, burns, and cuts. Also examine for knots, rust, dirt, paint, and grease or oil. Check
for damage caused by chemical corruption or excessive heat as evident with discoloration.
Examine for extreme exposure to sunlight and ultraviolet as demonstrated by desiccation.
Check for any missing or loose screws or nuts and any deformed or damaged components.
Examine the external housing for cracks, breaks, or warping.
Review the integral anchor loop and Connector for damage and deformation. The anchor
loop should rotate smoothly and be joined firmly to the housing. The Connector should also
rotate smoothly within the anchor loop.
Examine the overall SRD unit for any indications of deterioration or damage.
All labels must be intact and totally readable (see Section 8)
If an inspection reveals defects or damage to the equipment, remove the equipment from service.
7.2 Inspection Frequency:
Inspection by a competent person at regular intervals is required. The competent person will use the
information in Table 2, SRL Inspection Recommendations, to determine the inspection frequency. Use
Table 2 to determine the inspection frequency. Inspection by a factory authorized inspection entity at
regular intervals is also recommended.
Type of Use
Infrequent to
Light Use
Moderate to
Heavy Use
Severe to
Continuous
Use
7.3 Inspection Checklist:
Use Table 1: Guidelines for Cable SRL Inspection to inspect the SRL.
7.4 Inspection Results:
If an inspection reveals defects in or damage to the equipment, inadequate maintenance, or activated
fall indicators, remove the equipment from service.
7.5 Inspection Document:
Record inspection results on the Inspection Record provided below or on a similar document.
14
Table 1 - Guidelines for FT-X Web SRL-P Inspection
Table 2 - ANSI Z359.14-2021 SRL Inspection Recommendations
Application Examples
Rescue and Confined
Space, Factory
Maintenance
Transportation,
Residential
Construction, Utilities,
Warehouse
Commercial
Construction, Oil and Gas,
Mining
Conditions of Use
Good Storage Conditions, Indoor or
Infrequent
Outdoor use, Room
Temperature, Clean
Environments
Fair Storage Conditions, Indoor and
extended
outdoor use, All
temperatures, Clean or dusty
environments
Harsh Storage Conditions,
Prolonged or
Continuous outdoor Use, all
temperatures, Dirty
environments
Pass
Fail
Inspection Frequency
Competent Person
Annually
Semi-annually to
Annually
Quarterly to
Semi-annually